IEC 60079-0
Edition 7.0 2017-12
EXPLOSIVE ATMOSPHERES –
Part 0: Equipment – General requirements
INTERPRETATION SHEET 2
This interpretation sheet has been prepared by IEC technical committee 31: Equipment for
explosive atmospheres.
The text of this interpretation sheet is based on the following documents:
DISH Report on voting
31/1469/DISH 31/1486/RVDISH
Full information on the voting for the approval of this interpretation sheet can be found in the
report on voting indicated in the above table.
___________
Question:
How shall marking be shown for equipment covered by both the electrical and non-electrical
standards (IEC 60079 and ISO 80079 series)?
Answer:
Equipment which includes both an electrical part and a non-electrical part shall have
combined marking. For example:
Ex db h IIA T4 Gb
Ex h tb IIIC T135 °C Db
ICS 29.260.20
IEC 60079-0:2017-12/ISH2:2019-06(en-fr)
– 2 – IEC 60079-0:2017/ISH2:2019
IEC 2019
It will be clearer for the user that the combined risk of the electrical part and the non-electrical
part, covered by a single certificate, has been assessed for the complete equipment, stating
one EPL, one equipment Group and one temperature class for Gas and the same for Dust
(but showing a maximum surface temperature instead of a temperature class). It is also noted
that Ex Components are not marked with either a temperature class (Group II) or a maximum
surface temperature (Group III).
For equipment where separate certificates have been prepared, with one for the electrical
parts, and one for the non-electrical parts, it is appropriate to have separate electrical and
non-electrical marking strings, each with its own associated certificate number.
NOTE Additional guidance on the marking of assemblies is given in IEC TS 60079-46.