IEC 60335-2-89:2019/COR1:2019

Corrigendum 1 - Household and similar electrical appliances - Safety - Part 2-89: Particular requirements for commercial refrigerating appliances and ice-makers with an incorporated or remote refrigerant unit or motor-compressor

IEC 60335-2-89:2019/COR1:2019

Name:IEC 60335-2-89:2019/COR1:2019   Standard name:Corrigendum 1 - Household and similar electrical appliances - Safety - Part 2-89: Particular requirements for commercial refrigerating appliances and ice-makers with an incorporated or remote refrigerant unit or motor-compressor
Standard number:IEC 60335-2-89:2019/COR1:2019   language:English and French language
Release Date:23-Sep-2019   technical committee:SC 61C - Safety of refrigeration appliances for household and commercial use
Drafting committee:WG 4 - TC 61/SC 61C/WG 4   ICS number:97.130.20 - Commercial refrigerating appliances

 IEC 2019
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 60335-2-89 IEC 60335-2-89
Edition 3.0  2019-06 Édition 3.0  2019-06
HOUSEHOLD AND SIMILAR ELECTRICAL APPAREILS ÉLECTRODOMESTIQUES ET
APPLIANCES – SAFETY – ANALOGUES – SÉCURITÉ –
Part 2-89: Particular requirements for Partie 2-89: Exigences particulières pour les
commercial refrigerating appliances and ice-
appareils de réfrigération et fabriques de glace à
makers with an incorporated or remote usage commercial avec une unité de fluide
refrigerant unit or motor-compressor frigorigène ou un motocompresseur incorporés
ou à distance
CO RRI G E NDUM 1
Corrections to the French version appear after the English text.
Les corrections à la version française sont données après le texte anglais.
3 Terms and definitions
3.6.8 Replace:
3.6.8
By:
3.6.108
Replace:
Note 1 to entry: The following are not considered to be critical points:
– interconnecting joints between parts of the refrigerating circuit;
– pipies with a bended radius, measured along the centre line, of less than 2,5 times the external pipe
diameter;
– welded telescopic joints of the motor-compressor;
– welding of the pipes through the motor-compressor housing;
– welding of hermetic glass to metal seals (fusite).
By:
Note 1 to entry: The following are considered to be critical points:
– interconnecting joints between parts of the refrigerating circuit;
IEC 60335-2-89:2019-06/COR1:2019-09(en-fr)

– 2 – IEC 60335-2-89:2019/COR1:2019
 IEC 2019
– pipes with a bend radius, measured along the centre line, of less than 2,5 times the external pipe diameter.
Note 2 to entry: The following are not considered to be critical points:
– pipes with a bend radius, measured along the centre line, equal to or greater than 2,5 times the external
pipe diameter;
– welded telescopic joints of the motor-com
...

  • Relates Information
  • ISO 8130-9:1992

    ISO 8130-9:1992 - Coating powders
    09-28
  • EN 352-2:2020/FprA1

    EN 352-2:2021/oprA1:2023
    09-28
  • IEC TS 61158-4:1999

    IEC TS 61158-4:1999 - Digital data communications for measurement and control - Fieldbus for use in industrial control systems - Part 4: Data Link protocol specification Released:3/24/1999 Isbn:2831847656
    09-28
  • HD 566 S1:1990

    HD 566 S1:1998
    09-28
  • ISO 5131:1982/Amd 1:1992

    ISO 5131:1982/Amd 1:1992
    09-28
  • EN 60598-2-22:1990

    EN 60598-2-22:1996
    09-27
  • ISO 8504-2:1992

    ISO 8504-2:1992 - Preparation of steel substrates before application of paints and related products -- Surface preparation methods
    09-27
  • EN 12165:2024

    prEN 12165:2022
    09-27
  • IEC TS 61158-6:1999

    IEC TS 61158-6:1999 - Digital data communications for measurement and control - Fieldbus for use in industrial control systems - Part 6: Application Layer protocol specification Released:3/24/1999 Isbn:2831847613
    09-27
  • ISO 4252:1992

    ISO 4252:1992 - Agricultural tractors -- Operator's workplace, access and exit -- Dimensions
    09-27