IEC 60079-11:2006/ISH1:2019

Interpretation sheet 1 - Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"

IEC 60079-11:2006/ISH1:2019

Name:IEC 60079-11:2006/ISH1:2019   Standard name:Interpretation sheet 1 - Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
Standard number:IEC 60079-11:2006/ISH1:2019   language:English and French language
Release Date:12-Dec-2019   technical committee:SC 31G - Intrinsically-safe apparatus
Drafting committee:   ICS number:29.260.20 - Electrical apparatus for explosive atmospheres

 IEC 2019
INTERNATIONAL ELECTROTECHNICAL COMMISSION

____________
IEC 60079-11
Edition 5.0  2006-07
EXPLOSIVE ATMOSPHERES –
Part 11: Equipment protection by intrinsic safety "i"

INTERPRETATION SHEET 1
This interpretation sheet has been prepared by subcommittee 31G: Intrinsically-safe
apparatus, of IEC technical committee 31: Equipment for explosive atmospheres.
The text of this interpretation sheet is based on the following documents:
DISH Report on voting
31G/310/DISH 31G/313/RVDISH
Full information on the voting for the approval of this interpretation sheet can be found in the
report on voting indicated in the above table.
___________
Background
IEC 60079-11:2006 subclause 10.5.3 b) states the following:
The maximum surface temperature shall be determined as follows:
All current-limiting devices external to the cell or battery shall be short-circuited for the test.

Any external sheath (of paper or metal, etc.) not forming part of the actual cell enclosure shall
be removed for the test. The temperature shall be determined on the outer enclosure of each
cell or battery and the maximum figure taken. The test shall be carried out both with internal
current-limiting devices in circuit and with the devices short-circuited using 10 cells in each
case. The 10 samples having the internal current-limiting devices short-circuited shall be
obtained from the cell/battery manufacturer together with any special instructions or
precautions necessary for safe use and testing of the samples.
The intent of the cited paragraphs is to simulate an internal short inside a cell, by shorting the
cell’s external terminals for the purpose of thermal assessment.
It was found that two details have been misinterpreted in this subclause:
a) The subjects of this subclause are cells or batteries, while the intent is clearly to
simulate internal shorts inside cells and not inside batteries in which case the shorts
could be interpreted as being external to the cell(s) within a battery.
ICS 29.260.20
IEC 60079-11:2006-07/ISH1:2019-12(en-fr)

– 2 – IEC 60079-11:2006/ISH1:2019

 IEC 2019
b) It is unclear what constitutes a current limiting device that protects against internal

shorts.
A separator with shutdown function may be interpreted as a current limiting device that

protects against internal shorts by its function, but since it is a constructional part of the cell

that is not removable without invalidating the functionality of the basic cell, it is not a current
limiting device for the purposes of implementing the standard. Conversely, a CID (Current

interruption device), for example, is a switch that is triggered by increased pressure inside the

cell, and the cell’s functionality is not invalidated by the absence of the CID.

The reference to internal current limiting devices that protect against internal shorts in edition

6 was included to address unknown future cell technologies which could include such current

limiting devices, however at this time no such current limiting devices are known.
Question
For either Level of Protection “ia” or “ib”, what are the current limiting devices that are
required to be disabled (or equivalent e.g. not fitted, short-circuited or removed) by IEC
60079-11:2006, Subclause 10.5.3 b), and what are the current limiting devices that need not
be disabled?
Answer
All discrete protective devices that can be schematically represented as individual devices
apart from the cell are to be disabled for the purposes of testing according to IEC 60079-
11:2006, Subclause 10.5.3 b), regardless if they are located inside the cell or if they are
external to the cell. This includes, but is not limited to resistors, fuses, resettable fuses (NTC,
PTC, PPTC), CID (current interruption device), semiconductors, etc.
Features that provide essential cell functions, such as a separator with shutdown function or
the ohmic resistance of the electrolyte, are not considered current limiting devices in the
sense of this clause and need not be shorted or removed, and such cells can be considered
for Level of Protection “ia”.
 IEC 2019
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

____________
IEC 60079-11
Edition 5.0  2006-07
ATMOSPHÈRES EXPLOSIVES –
Partie 11: Protection de l'équipement par sécurité intrinsèque "i"

FEUILLE D'INTERPR É TA TI O N 1

Cette feuille d’interprétation a été établie par le sous-comité 31G: Matériels à sécurité
intrinsèque, du comit
...

  • Relates Information
  • ISO 8130-9:1992

    ISO 8130-9:1992 - Coating powders
    09-28
  • EN 352-2:2020/FprA1

    EN 352-2:2021/oprA1:2023
    09-28
  • IEC TS 61158-4:1999

    IEC TS 61158-4:1999 - Digital data communications for measurement and control - Fieldbus for use in industrial control systems - Part 4: Data Link protocol specification Released:3/24/1999 Isbn:2831847656
    09-28
  • HD 566 S1:1990

    HD 566 S1:1998
    09-28
  • ISO 5131:1982/Amd 1:1992

    ISO 5131:1982/Amd 1:1992
    09-28
  • EN 60598-2-22:1990

    EN 60598-2-22:1996
    09-27
  • ISO 8504-2:1992

    ISO 8504-2:1992 - Preparation of steel substrates before application of paints and related products -- Surface preparation methods
    09-27
  • EN 12165:2024

    prEN 12165:2022
    09-27
  • IEC TS 61158-6:1999

    IEC TS 61158-6:1999 - Digital data communications for measurement and control - Fieldbus for use in industrial control systems - Part 6: Application Layer protocol specification Released:3/24/1999 Isbn:2831847613
    09-27
  • ISO 4252:1992

    ISO 4252:1992 - Agricultural tractors -- Operator's workplace, access and exit -- Dimensions
    09-27