ISO/IEC 14763-4
Edition 2.0 2021-03
INTERNATIONAL
STANDARD
Information technology – Implementation and operation of customer premises
cabling –
Part 4: Measurement of end-to-end (E2E) links, modular plug terminated links
(MPTLs) and direct attach cabling
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about
ISO/IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address
below or your local IEC member National Committee for further information.
IEC Central Office Tel.: +41 22 919 02 11
3, rue de
CH-1211 Geneva 20
Switzerland
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigendum or an amendment might have been published.
IEC publications search - webstore.iec.ch/advsearchform IEC online collection - oc.iec.ch
The advanced search enables to find IEC publications by a Discover our powerful search engine and read freely all the
variety of criteria (reference number, text, technical publications previews. With a subscription you will always
committee, …). It also gives information on projects, replaced have access to up to date content tailored to your needs.
and withdrawn publications.
Electropedia - www.electropedia.org
IEC Just Published - webstore.iec.ch/justpublished
The world's leading online dictionary on electrotechnology,
Stay up to date on all new IEC publications. Just Published
containing more than 22 000 terminological entries in English
details all new publications released. Available online and
and French, with equivalent terms in 18 additional languages.
once a month by email.
Also known as the International Electrotechnical Vocabulary
(IEV) online.
IEC Customer Service Centre - webstore.iec.ch/csc
If you wish to give us your feedback on this publication or
need further assistance, please contact the Customer Service
.
ISO/IEC 14763-4
Edition 2.0 2021-03
INTERNATIONAL
STANDARD
Information technology – Implementation and operation of customer premises
cabling –
Part 4: Measurement of end-to-end (E2E) links, modular plug terminated links
(MPTLs) and direct attach cabling
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
ICS 35.200 ISBN 978-2-8322-9478-9
– 2 – ISO/IEC 14763-4:2021 ISO/IEC 2021
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms, definitions and abbreviated terms . 8
3.1 Terms and definitions . 8
3.2 Abbreviated terms . 8
4 Conformance . 8
5 Transmission performance of E2E links, MPTLs and direct attach cabling . 8
6 Transmission limits of E2E link, MPTLs and direct attach cabling . 8
7 Reference planes of E2E link, MPTL and direct attach cabling . 9
7.1 Reference planes of E2E link . 9
7.2 Reference planes of MPTL . 9
7.3 Reference planes of direct attach cabling . 10
8 Testing . 11
8.1 General . 11
8.2 Laboratory testing of E2E link, MPTL and direct attach cabling . 11
8.3 Field testing of E2E link, MPTL and direct attach cabling . 11
8.3.1 Basic criteria . 11
8.3.2 Requirements of field test equipment . 12
8.3.3 Field test measurement parameters . 12
9 Test head requirements . 12
9.1 General . 12
9.2 Additional test head requirements in accordance with the IEC 60603-7 series . 12
9.3 Test head requirements of IEC 61076-2-101 . 13
9.4 Test head requirements of IEC 61076-2-109 . 13
Annex A (informative) Example performance of E2E link test heads . 14
A.1 Example Category 5 test head performance . 14
A.2 Example Category 6 test head performance . 14
Annex B (normative) Test regime for reference performance and installation
performance of E2E link, MPTL and direct attach cabling . 16
Bibliography . 18
Figure 1 – Reference planes of E2E links . 9
Figure 2 – Reference planes of 2-connection MPTL . 10
Figure 3 – Reference planes of 3-connection MPTL . 10
Figure 4 – Reference planes of direct attach cabling . 11
Table 1 – Transmission performance limits . 8
Table 2 – Overview level for field test equipment of performance of E2E link, direct
attach cabling and MPTLs . 12
Table A.1 – Category 5 test head of E2E link de-embedded NEXT performance in the
frequency range 50 MHz ≤ f < 100 MHz . 14
Table A.2 – Category 6 test head of E2E link de-embedded NEXT performance in the
frequency range 50 MHz ≤ f < 250 MHz . 15
Table B.1 – Reference Classes of E2E link, direct attach cabling and MPTL . 16
Table B.2 – Test regime for reference performance and installation performance of
E2E link, direct attach cabling and MPTL . 16
– 4 – ISO/IEC 14763-4:2021 ISO/IEC 2021
INFORMATION TECHNOLOGY –
IMPLEMENTATION AND OPERATION
OF CUSTOMER PREMISES CABLING –
Part 4: Measurement of end-to-end (E2E) links, modular
plug terminated links (MPTLs) and direct attach cabling
FOREWORD
1) ISO (the International Organization for Standardization) and IEC (the International Electrotechnical Commission)
form the specialized system for worldwide standardization. National bodies that are members of ISO or IEC
participate in the development of International Standards through technical committees established by the
respective organization to deal with particular fields of technical activity. ISO and IEC technical committees
collaborate in fields of mutual interest. Other international organizations, governmental and non-governmental, in
liaison with ISO and IEC, also take part in the work. In the field of information technology, ISO and IEC have
established a joint technical committee, ISO/IEC JTC 1.
2) The formal decisions or agreements of IEC and ISO on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested IEC National Committees and ISO member bodies.
3) IEC, ISO and ISO/IEC publications have the form of recommendations for international use and are accepted by
IEC National Committees and ISO member bodies in that sense. While all reasonable efforts are made to ensure
that the technical content of IEC, ISO and ISO/IEC publications is accurate, IEC or ISO cannot be held
responsible for the way in which they are used or for any misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees and ISO member bodies undertake to
apply IEC, ISO and ISO/IEC publications transparently to the maximum extent possible in their national and
regional publications. Any divergence between any ISO, IEC or ISO/IEC publication and the corresponding
national or regional publication should be clearly indicated in the latter.
5) ISO and IEC do not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. ISO or IEC are not responsible for
any services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or ISO or its directors, employees, servants or agents including individual experts
and members of their technical committees and IEC National Committees or ISO member bodies for any personal
injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including
legal fees) and expenses arising out of the publication of, use of, or reliance upon, this ISO/IEC publication or any
other IEC, ISO or ISO/IEC publications.
8) Attention is drawn to the normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this ISO/IEC publication may be the subject of
patent rights. ISO and IEC shall not be held responsible for identifying any or all such patent rights.
International Standard ISO/IEC 14763-4 was prepared by subcommittee 25: Interconnection of
information technology equipment, of ISO/IEC joint technical committee 1: Information
technology.
This second edition cancels and replaces the first edition published in 2018. This edition
constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
• measurement of the transmission performance of modular plug terminated link (MPTL) and
direct attach cabling were added.
• Additional requirements of test head designs of E2E link were introduced.
The text of this standard is based on the following documents:
FDIS Report on voting
JTC1-SC25/2997/FDIS JTC1-SC25/3010/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the ISO/IEC 14763 series, published under the general title Information
technology – Implementation and operation of customer premises cabling, can be found on the
IEC and ISO websites.
– 6 – ISO/IEC 14763-4:2021 ISO/IEC 2021
INTRODUCTION
The testing of balanced cabling channels in accordance with ISO/IEC 11801-1 does not verify
the performance of the free connector at each end of the channel.
This document describes the measurement of three cabling structures which verifies the
performance of their terminating connectors. These are:
a) end-to-end (E2E) link of ISO/IEC 11801-3,
b) modular plug terminated link (MPTL) of ISO/IEC TR 11801-9910,
c) direct attach cabling of ISO/IEC TR 11801-9907.
This measurement includes the transmission performance of the connector components which
terminate the cabling under test.
INFORMATION TECHNOLOGY –
IMPLEMENTATION AND OPERATION
OF CUSTOMER PREMISES CABLING –
Part 4: Measurement of end-to-end (E2E) links, modular
plug terminated links (MPTLs) and direct attach cabling
1 Scope
This part of ISO/IEC 14763 specifies the measurement of two- and four-pair balanced cabling
of
a) end-to-end (E2E) link Class D, E and E ;
A
b) modular plug terminated links (MPTLs) of Class D, E, E , F, F and of Class I and II;
A A
c) direct attach cabling of Class D, E, E , F, F and of Class I and II.
A A
The free connectors which terminate two and four pairs in field an
...