IEC 60384-24
Edition 3.0 2021-07
REDLINE VERSION
INTERNATIONAL
STANDARD
colour
inside
Fixed capacitors for use in electronic equipment –
Part 24: Sectional specification – Fixed tantalum electrolytic surface mount
capacitors with conductive polymer solid electrolyte
your local IEC member National Committee for further information.
IEC Central Office Tel.: +41 22 919 02 11
3, rue de
CH-1211 Geneva 20
Switzerland
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigendum or an amendment might have been published.
IEC publications search - webstore.iec.ch/advsearchform IEC online collection - oc.iec.ch
The advanced search enables to find IEC publications by a Discover our powerful search engine and read freely all the
variety of criteria (reference number, text, technical publications previews. With a subscription you will always
committee, …). It also gives information on projects, replaced have access to up to date content tailored to your needs.
and withdrawn publications.
Electropedia - www.electropedia.org
IEC Just Published - webstore.iec.ch/justpublished
The world's leading online dictionary on electrotechnology,
Stay up to date on all new IEC publications. Just Published
containing more than 22 000 terminological entries in English
details all new publications released. Available online and
and French, with equivalent terms in 18 additional languages.
once a month by email.
Also known as the International Electrotechnical Vocabulary
(IEV) online.
IEC Customer Service Centre - webstore.iec.ch/csc
If you wish to give us your feedback on this publication or
need further assistance, please contact the Customer Service
.
IEC 60384-24
Edition 3.0 2021-07
REDLINE VERSION
INTERNATIONAL
STANDARD
colour
inside
Fixed capacitors for use in electronic equipment –
Part 24: Sectional specification – Fixed tantalum electrolytic surface mount
capacitors with conductive polymer solid electrolyte
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
ICS 31.060.40; 31.060.50 ISBN 978-2-8322-4176-9
– 2 – IEC 60384-24:2021 RLV © IEC 2021
CONTENTS
FOREWORD. 5
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 8
4 Preferred ratings and characteristics . 8
4.1 Preferred characteristics . 8
4.2 Preferred values of ratings . 8
4.2.1 Nominal capacitance (C ) . 8
N
4.2.2 Tolerance on nominal capacitance . 8
4.2.3 Rated voltage (U ) . 9
R
4.2.4 Category voltage (U ) . 9
C
4.2.5 Surge voltage (U or U ) . 9
RS CS
4.2.6 Rated temperature . 9
5 Test and measurement procedures . 10
5.1 General . 10
5.2 Preliminary drying . 10
5.3 Measuring conditions . 10
5.4 Mounting . 10
5.4.1 General . 10
5.4.2 Initial inspections . 10
5.4.3 Test conditions . 10
5.4.4 Final inspections and requirements . 10
5.5 Visual examination and check of dimensions . 10
5.5.1 General . 10
5.5.2 Visual examination and check of dimensions . 10
5.5.3 Requirements . 10
5.6 Electrical tests . 11
5.6.1 Leakage current . 11
5.6.2 Capacitance . 11
5.6.3 Tangent of loss angle (tan δ) . 11
5.6.4 Equivalent series resistance (ESR) (if required) . 12
5.7 Resistance to soldering heat . 12
5.7.1 General . 12
5.7.2 Initial inspections . 12
5.7.3 Test conditions . 12
5.7.4 Recovery . 12
5.7.5 Final inspections and requirements . 12
5.8 Solderability . 12
5.8.1 General . 12
5.8.2 Final inspections and requirements . 12
5.9 Shear test . 12
5.10 Substrate bending test (if required) . 13
5.10.1 General . 13
5.10.2 Initial inspections . 13
5.10.3 Test conditions . 13
5.10.4 Final inspections and requirements . 13
5.11 Rapid change of temperature . 13
5.11.1 General . 13
5.11.2 Initial inspections . 13
5.11.3 Test conditions . 13
5.11.4 Recovery . 13
5.11.5 Final inspections and requirements . 13
5.12 Climatic sequence . 13
5.12.1 General . 13
5.12.2 Initial inspections . 13
5.12.3 Dry heat . 14
5.12.4 Damp heat, cyclic, test Db, first cycle . 14
5.12.5 Cold. 14
5.12.6 Damp heat, cyclic, test Db, remaining cycles . 14
5.12.7 Recovery . 14
5.12.8 Final inspections and requirements . 14
5.13 Damp heat, steady state . 14
5.13.1 General . 14
5.13.2 Initial inspections . 14
5.13.3 Test conditions . 14
5.13.4 Recovery . 14
5.13.5 Final inspections and requirements . 14
5.14 Characteristics at high and low temperature . 15
5.14.1 General . 15
5.14.2 Initial inspections and requirements . 15
5.15 Surge voltage . 15
5.15.1 General . 15
5.15.2 Initial inspections . 15
5.15.3 Test conditions . 15
5.15.4 Recovery . 15
5.15.5 Final inspections and requirements . 16
5.16 Endurance . 16
5.16.1 General . 16
5.16.2 Initial inspections . 16
5.16.3 Test conditions . 16
5.16.4 Recovery . 16
5.16.5 Final inspections and requirements . 16
5.17 Component solvent resistance (if required) . 16
5.18 Solvent resistance of marking (if required) . 16
5.19 High surge current (if required) . 16
5.20 Storage at high temperature . 16
5.20.1 General . 16
5.20.2 Initial inspections . 16
5.20.3 Test conditions . 17
5.20.4 Recovery . 17
5.20.5 Final inspections and requirements . 17
6 Marking . 17
6.1 General . 17
6.2 Information for marking . 17
6.3 Marking on capacitors . 17
– 4 – IEC 60384-24:2021 RLV © IEC 2021
6.4 Marking on packaging .
...