1. The location of the equipment should have smooth ventilation, there should be sufficient air inlets at the generator end, and there should be air outlets at the diesel engine end. The air outlet area should be more than 1.5 times larger than the water tank area (for reference only: (Fujian Yanan diesel generator) Yaxiaonan will answer for you)
2 . be kept clean to avoid placing near objects that may generate corrosive gases and vapors such as acids and alkalis. Fire-fighting equipment should be equipped if possible;
3. When used indoors, the smoke exhaust pipe must be directed outside. The diameter of the pipe must be ≥ the diameter of the smoke outlet pipe. the silent. The diameter of the connected pipe must be There must not be more than 3 elbows to ensure smooth flow of the smoke evacuation, and the tuyau should be tilted downward 5-10 degrees to prevent rainwater from entering if the exhaust pipe is installed; vertically upwards, it is necessary to install a rain cover; p>
4. When concrete is used as a foundation, a level ruler should be used to measure its level during installation to ensure the unit is secured to a support. level foundation. There must be special anti-vibration pads or anchor bolts between the unit and the foundation;
5. The unit shell must have reliable protective grounding. For generators that require a neutral point to be directly grounded, this is the case. The necessary professionals must carry out the neutral grounding and be equipped with lightning protection equipment. It is strictly prohibited to use mains grounding equipment to directly ground the neutral point ;
6. the mains must be very reliable to prevent power transmission. The reliability of the two-way switch wiring must be inspected and certified by the local power supply department.
Inlet design of diesel generator set
The design wind speed is 6 m/s.
According to the exhaust volume of different units divided by the wind speed, the effective exhaust area is divided by the space coefficient of the silencer group (generally 0.6). This will give you the surface area of the air outlet. If the exhaust air is to rotate, the surface area must be increased and the surface area of each 90 degree elbow is increased by 15%
The air inlet volume is the volume of air exhausted plus the gas volume plus the exhaust volume for heat dissipation in the computer room.
Relevant data on diesel generator room design
Unit power (kW) Generator roomstandard chines (length, width and height in mm) Exhaust shaft and outlet area with fan (㎡) Air inlet area ㎡ (plus fan) Air inlet area ㎡ (natural air inlet ) Fan exhaust flow (m?/min) Unit size (length, width and height mm) Weight (kg) Area between fuel tanks (㎡)
< p>220 7000×4000 ×4500 1.6 2.0 4.0 490 3000×980×1530 3100 2275 7200×4000×4500 1.7 2.1 4.2 490 3150×980×1530 3250 2 < /p>
310 7200×400 0×4500 1.7 2.1 4.2490 3150×980×1530 3400 3
330 7300×4250×4500 2.3 3.0 6, 0 490 3300×1250×1800 3600 3
360 7300×4380×4500 2.6 3.2 6 . 4 490 3300 ×1380×1550 3700 3
400 7550×4250×4500 2.6 3.2 6.4 588 3550×1250×1800 4350 3
440 7750×4250 ×4500 3.0 3.5 7. 0 588 3 750×1250 ×1800 4800 4
500 7750×4920×4500 3.0 4.5 9.0 735 3750×1920×2300 5000 4
550 7750×4920×4500 3.2 4.5 9.0 735 3750× 1 920×2300 5400 4
660 8650×4650×5000 4.0 6.0 12.0 900 4650×1630×2320 9250 4
704 8650×4650×5000 4.0 6.0 12.0 900 4650×1630 ×2320 9350 5
1. Concerning the well of the smoke evacuation pipe ( mandatory), the manufacturer requires a minimum clearance: 800x800 mm for a generator; 1200 x 1200 mm for two generators. Increase appropriately when conditions permit.
2. Regarding the clearance size of the spray dusting room (suitable for installation): 1800 x 2000 mm when a generator is used; 1800 x 2800 mm when two generators are used together.