The ambient temperature of the generator itself during normal use should not exceed 50 degrees. If the normal temperature has reached more than 40 degrees and the diesel generator itself will emit a lot of heat when in use, the generator room will not. be well ventilated. So good, the temperature in the computer room will definitely rise, and the generator will of course go on strike. Therefore, it is recommended that the customer open all doors and windows in the generator room and replace all hot water in the water tank with cold water. The temperature of the generator room will drop immediately and the generator set can be used normally.
Diesel generatorOil pressure is normal in the range of 2-8 kg, water temperature is normal below 93 Celsiusand the oil temperature is normal. She is generalapproximately 10 degrees Celsius higher than the water temperature. Cummins diesel generator set type: rotating magnetic field, single bearing, 4 poles, brushless, anti-drip structure, insulation grade H, conforming to GB766, BS5000, IEC34-1 quality standards. The generator can be used in sandy, salty, seawater and chemically corrosive environments.
Cummins is the largest US investment company in China. Cummins has invested more than 140 million US dollars in China, including Dongfeng Cummins diesel generator sets and Chongqing Cummins diesel generator sets. As the largest foreign investor in China's automobile industry, Cummins owns eight joint ventures and wholly-owned manufacturing companies in China, including. Dongfeng Cummins produces B, C and L series diesel engines.
Six key points for myDiesel Generator Fuel System Maintenance
1. Generally, the diesel filter element of the diesel engine of the diesel generator set needs to be cleaned once every 100 hours of operation.
2. Work for 500 hours, clean the fuel tank and pipelines, remove carbon deposits on the injector parts, calibrate the injection pressure and check the injection atomization quality.
3. There should be no leaks in the pipe joints and oil circuit seals.
4. Diesel must be precipitated and purified before being injected into the fuel tank.
5. When a diesel engine is used for the first time after disassembly or has been left unused for a long time, the gas in the oil circuit must be released. Bleeding method: turn on the fuel switch and loosen the pump bleeder screwpe fuel injection.
6. Whether the generator's diesel engine is running or idling, the fuel tank filler cap should be closed to prevent stolen items and dust from falling into the fuel tank.