Need to detect:
Pm, solar module output power
Voc: open circuit voltage
Vop: operating voltage
Isc: Short-circuit current
Iop: Operating current
Dimensions:
Weight:
Coefficient of peak temperature:
Open circuit voltage temperature coefficient:
Short circuit current temperature coefficient:
The insulator is subjected to 1000 V DC plus twice the maximum system voltage for 1 minute.
For components with an area of less than 0.1 m2, the insulation resistance should not be less than 400 M?. For components with an area greater than 0.1 m2, the test insulation resistance multiplied by the component area shall not be lower. greater than 40M? m2. Use 500V or system maximum during testing. The high voltage value
is usually 3000 V
.