This may be caused by the following two reasons:
First: It is caused by the excessive pressure of cold water during the filling process of water. The water surface in the water tank is wavy. When the peak of the water surface hits the fourth probe of the sensor, the meter indicates that the water is full. When the water surface calms down, the actual water level may not reach the level. fourth level and will show three levels, but it's not just three levels. The water level is only slightly lower than the four bar water level, which does not have much impact on the water capacity of the water tank and the user's usage. You can rest assured
Second: there is a leak in the outer host part, and the leak is relatively slow; this requires letting maintenance personnel carry out repairs
Judgment method: after filling out theWater in the morning or evening, restart the water replenishment function in the evening or morning before using water. If the water reaches 100% or 4 levels in a short time, it proves that it is a general situation. supply is long, this proves that there may be water leakage outside (make sure no one uses water between filling water and detecting), which requires repairs by professionals