Reinforced Mesh Manufacturer Telephone Number: 15030806331.
Reinforced Mesh Factory Co., Ltd. is located in Anping County, Hebei Province, known as the "hometown of wire mesh in China". adjacent to the Beijing-Guangzhou Railway and the Beijing-Shenzhen Expressway in the west, adjacent to the Beijing-Kowloon Railway and the Beijing-Shanghai Expressway in the east, and connected to it by the Shihuang Expressway to the south, it is a comprehensive enterprise integrating production, domestic sales, foreign trade, import and export.
The company has been committed to a development direction of "valuing credibility, seeking markets, manufacturing high-quality products and creating high efficiency" for many years, constantly providing customers with high-quality products and services, and enable the production of products to achieve quality, scale andstandardization, making every aspect of the service perfect on a day-to-day basis.
The main products are:
Products include steel fence, construction mesh, underfloor heating mesh, galvanized mesh, plastic impregnated mesh, support for coal mine mesh, bridge steel mesh, construction steel mesh, tunnel steel mesh, Q195 black bright wire, Q235 iron bright wire, annealed wire, etc. Widely used in coal mining, petroleum, chemical industry, construction, filtration, machinery, aviation, agricultural production, animal husbandry and other fields.
What is the anti-cracking belt for underfloor heating?
The price of underfloor heating mesh is about 3-5 yuan.
The floor heating mesh, also known as the floor heating mesh, special mesh for heatingunderfloor heating and steel wire mesh, is made of black iron wire or drawn wire and is welded. mesh surface and solder joints. It is strong, has a uniform mesh and is easy to transport. Its function is to improve the overall strength of the insulation board and facilitate the installation and fixing of the heating pipe.
Specifications: The diameter of the floor heating mesh wire is mainly 1.5-4mm. The thickness of the wire diameter determines the quality of the project and the bearing capacity of the soil (based on the specific needs of the project). ). The mesh holes are 5*5cm, 10*10cm, 5*10cm and 6*6cm. The commonly used floor heating mesh specifications are 2mm wire diameter, 10cm × 10cm mesh, and 1m × 2m length and width.
Floor heating mesh is also called steel wire mesh. Its functions in heating projects par the ground are:
1. It is convenient for pipe installation and the construction speed is faster. should be placed above the wire mesh. Secure the pipe.
2. It can improve the bearing capacity of the roof and avoid the occurrence of undesirable phenomena such as ground cracking, cracking and collapse.
3. The thermal conductivity of the steel mesh is very good, which can promote uniform heat dissipation.
4. The most important point is thermal insulation and crack prevention. Steel wire mesh is a kind of heat insulation and crack prevention material in construction projects. The construction effect is very good and it has always been approved. the construction sector.
What are the application advantages of hot immersion heating mesh?
< p>Once the heating pipes arethe floor laid, the anti-crack strips are often placed only on the first layer. Its function is to stretch the cement that will be covered on the floor heating pipe in layers to avoid cracking, so putting more layers is of little use.Floor heating mesh, also known as floor heating mesh and special floor heating mesh, is made of Q235 low carbon steel wire of high quality welded together. It has the characteristics of flat mesh surface and firm welding. uniform mesh joints and holes. Its function is to improve the overall strength of the insulation board and facilitate the installation and fixing of the heating pipe. The specifications of commonly used floor heating mesh are: wire diameter 2mm, mesh 10cm × 10cm, length and width 1m × 2m.
Superimposed length of the anti-crack mesh for heating bythe ground
1. The hot-dip galvanized steel wire mesh for floor heating is automatically butt-welded by hot-dip galvanized wire, with firm welding points and smooth mesh surface. It has the advantages of mechanized production and large daily output, and is particularly suitable for underfloor heating construction.
2. The wire diameter can be thickened or thinned according to the mesh size, and the price is relatively moderate.
3. Can be mass produced as required. The color surface is black or galvanized or sprayed with white baking paint or green paint.
4. Used in professional projects for the construction of underfloor heating and building partitions or external insulation.
5. It can easily fix the pipes to prevent them from being misaligned during the ash spreading process;
6. He improveseffectively the bearing capacity of the ground and pipes. are not easily crushed;
7. It can prevent floor cracks;
8. The floor heating mesh can effectively accelerate heat dissipation and increase heating efficiency.
The surface of the mesh is very smooth without additional treatment, the solder joints are firm, and all solder joints are smooth and without protrusions. The mesh after anti-rust treatment has good anti-rust and anti-corrosion effects. .
What role can the heating mesh play?
When overlapping the anti-cracking mesh, the overlap on both sides should not be less than 200 . ~300mm.
The functions of the anti-crack mesh for underfloor heating:
1. It may have a fixing effect on installed pipes. Lay the underfloor heating mesh on the surface of the insulation. Layer and tie it with nylon with afixed pipe. It can make the construction speed faster, construction positioning accurate, and the overall effect of pipeline installation better.
2. It is useful to improve the local bearing capacity of the floor in places with large floor loads, such as processing workshops and garages, underfloor heating mesh used for underfloor heating can increase the resistance overall soil. the soil structure and avoid soil rupture and collapse?.
3. The underfloor heating mesh is also very effective in dissipating heat. Since steel bars have relatively strong thermal conductivity, the ground dissipates heat very evenly and quickly.
4. To prevent floor cracks, a floor heating mesh should be laid between the pipes and the concrete. The reason for the floor cracking was that the heating mesh was not used and theconcrete on the ground was too thin.
What should you pay attention to before installing and laying an underfloor heating network?
1. When the steel bars are thick and the welded mesh cannot be bent, 1-2 less steel bars can be welded to the ends of the welded mesh, then the two ends are inserted into the beam and tied with straight bars. Use on-site bonding methods to compensate for reduced transverse steel bars and additional steel bars.Each node connected to the welded mesh must be bonded with steel wire.
2. Before installing the underfloor heating mesh, an installation plan for the underfloor heating mesh must be drawn up. When installing underfloor heating mesh, installation guidelines should be based on on-site and on-site practice. the efficiency of the personnel responsible for the equipment.
3. For the welded mesh which must be ancD at both ends in the beam, when the longitudinal steel bars of the floor heating mesh are thin, use the bending deformation function of the floor heating mesh to bend first. the middle part of the welded mesh upwards. Make sure both ends can be inserted into the beam one after the other, then lay the floor heating mesh flat.
4. Between the ends of the welded mesh, the overlap length of the steel bar cover joint shall not be less than 1.3 times the anchor length la and shall not be less than 200 mm in the area of overlap. , each welded mesh for floor heating There shall be no less than one transverse steel bar on each sheet of floor heating mesh, and the distance between one transverse steel bar outside the two underfloor heating mesh sheets should not be less than 50 mm.
5. When one of the two underfloor heating mesh sheets in the overlapping area has no transverse steel bars, the overlapping length of the ribbed underfloor heating mesh sheet shall be 1.3 times the anchor length la and must not be less than 300 ㎜. When the diameter d of the longitudinally stressed steel bars in the overlap area is ≥ 10 mm, the overlap length should be increased by 5 days.
Floor heating mesh is also called steel wire mesh. Its functions in underfloor heating projects are:
1. It is convenient for installing pipes and pipes. the construction speed is fast. The pipe must be fixed above the steel mesh.
2. Avoid the occurrence of undesirable phenomena such as cracks, cracks and floor collapses.
3. The thermal conductivity of the steel mesh is verys good, which can promote uniform heat dissipation.