The domestic diesel generator cannot turn on electronically
First confirm the problem that the diesel generator cannot start
The first is electricity: battery, electric motor;
The second is oil: valves or pipeline leaks;
The third is ambient temperature: the temperature is too low and there is no of preheating device, making it difficult to start the diesel engine;
Fault How to solve the problem
a: The battery voltage is insufficient or the discharge current is insufficient
Troubleshooting method: Charge the battery and replace it if necessary.
b: There is air or blockage in the fuel line.
Troubleshooting method: Loosen the diesel filter purge bolt. Use a manual oil pump to pump until there are no more bubbles in the fuel. Replace the filter if necessary.
c : Electrical fault
Troubleshooting method: Check the starter switch for poor contact. Check the start relay and replace it if necessary.
d: Water entering the combustion chamber
Troubleshooting method: Analyze the cause and contact authorized service personnel. If water has entered, please do not attempt to start again.