SIST EN 60898-1:2004/IS1:2007

Electrical accessories - Circuit breakers for overcurrent protection for household and similar installations -- Part 1: Circuit-breakers for a.c. operation

SIST EN 60898-1:2004/IS1:2007

Name:SIST EN 60898-1:2004/IS1:2007   Standard name:Electrical accessories - Circuit breakers for overcurrent protection for household and similar installations -- Part 1: Circuit-breakers for a.c. operation
Standard number:SIST EN 60898-1:2004/IS1:2007   language:English language
Release Date:27-Sep-2007   technical committee:EPR - Electrical accessories
Drafting committee:   ICS number:29.120.50 - Fuses and other overcurrent protection devices
SLOVENSKI STANDARD
SIST EN 60898-1:2004/IS1:2007
01-november-2007
(OHNWULþQLSULERU2GNORSQLNL]DQDGWRNRYQR]DãþLWR]DJRVSRGLQMVNHLQSRGREQH
LQVWDODFLMH±GHO2GNORSQLNL]DL]PHQLþQHWRNRYH
Electrical accessories - Circuit breakers for overcurrent protection for household and
similar installations -- Part 1: Circuit-breakers for a.c. operation
Elektrisches Installationsmaterial - Leitungsschutzschalter für Hausinstallationen und
ähnliche Zwecke -- Teil 1: Leitungsschutzschalter für Wechselstrom (AC)
Petit appareillage électrique - Disjoncteurs pour la protection contre les surintensités
pour installations domestiques et analogues -- Partie 1: Disjoncteurs pour le
fonctionnement en courant alternatif
Ta slovenski standard je istoveten z: EN 60898-1:2003/IS1:2007
ICS:
29.120.50 9DURYDONHLQGUXJD Fuses and other overcurrent
PHGWRNRYQD]DãþLWD protection devices
SIST EN 60898-1:2004/IS1:2007 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

EN 60898-1/IS1

Interpretation Sheet 1

EN 60898-1:2003
English version
___________

Foreword
This Interpretation Sheet to the European Standard EN 60898-1:2003 was prepared by the Interpretation
Panel of the Technical Committee CENELEC TC 23E, Circuit breakers and similar devices for household
and similar applications. The text of the draft was submitted to the Unique Acceptance Procedure and was
approved by CENELEC on 2007-05-07.

First paragraph of Subclauses 9.5 and 8.1.5.2
9.5 Tests of reliability of screw-type terminals for external copper conductors
Compliance with the requirements of 8.1.5 is checked…
8.1.5.2 Circuit-breakers shall be provided with terminals which shall allow the connection of copper
conductors having
...

  • Relates Information
  • ISO 8130-9:1992

    ISO 8130-9:1992 - Coating powders
    09-28
  • EN 352-2:2020/FprA1

    EN 352-2:2021/oprA1:2023
    09-28
  • IEC TS 61158-4:1999

    IEC TS 61158-4:1999 - Digital data communications for measurement and control - Fieldbus for use in industrial control systems - Part 4: Data Link protocol specification Released:3/24/1999 Isbn:2831847656
    09-28
  • HD 566 S1:1990

    HD 566 S1:1998
    09-28
  • ISO 5131:1982/Amd 1:1992

    ISO 5131:1982/Amd 1:1992
    09-28
  • EN 60598-2-22:1990

    EN 60598-2-22:1996
    09-27
  • ISO 8504-2:1992

    ISO 8504-2:1992 - Preparation of steel substrates before application of paints and related products -- Surface preparation methods
    09-27
  • EN 12165:2024

    prEN 12165:2022
    09-27
  • IEC TS 61158-6:1999

    IEC TS 61158-6:1999 - Digital data communications for measurement and control - Fieldbus for use in industrial control systems - Part 6: Application Layer protocol specification Released:3/24/1999 Isbn:2831847613
    09-27
  • ISO 4252:1992

    ISO 4252:1992 - Agricultural tractors -- Operator's workplace, access and exit -- Dimensions
    09-27