SIST EN 60898-1:2004/IS4:2007

Electrical accessories - Circuit breakers for overcurrent protection for household and similar installations -- Part 1: Circuit-breakers for a.c. operation

SIST EN 60898-1:2004/IS4:2007

Name:SIST EN 60898-1:2004/IS4:2007   Standard name:Electrical accessories - Circuit breakers for overcurrent protection for household and similar installations -- Part 1: Circuit-breakers for a.c. operation
Standard number:SIST EN 60898-1:2004/IS4:2007   language:English language
Release Date:02-Oct-2007   technical committee:EPR - Electrical accessories
Drafting committee:   ICS number:29.120.50 - Fuses and other overcurrent protection devices
SLOVENSKI STANDARD
SIST EN 60898-1:2004/IS4:2007
01-november-2007
(OHNWULþQLSULERU±2GNORSQLNL]DQDGWRNRYQR]DãþLWR]DJRVSRGLQMVNHLQSRGREQH
LQVWDODFLMH±GHO2GNORSQLNL]DL]PHQLþQHWRNRYH
Electrical accessories - Circuit breakers for overcurrent protection for household and
similar installations -- Part 1: Circuit-breakers for a.c. operation
Elektrisches Installationsmaterial - Leitungsschutzschalter für Hausinstallationen und
ähnliche Zwecke -- Teil 1: Leitungsschutzschalter für Wechselstrom (AC)
Petit appareillage électrique - Disjoncteurs pour la protection contre les surintensités
pour installations domestiques et analogues -- Partie 1: Disjoncteurs pour le
fonctionnement en courant alternatif
Ta slovenski standard je istoveten z: EN 60898-1:2003/IS4:2007
ICS:
29.120.50 9DURYDONHLQGUXJD Fuses and other overcurrent
PHGWRNRYQD]DãþLWD protection devices
SIST EN 60898-1:2004/IS4:2007 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

EN 60898-1/IS4

Interpretation Sheet 4

EN 60898-1:2003
English version
___________

Foreword
This Interpretation Sheet to the European Standard EN 60898-1:2003 was prepared by the Interpretation
Panel of the Technical Committee CENELEC TC 23E, Circuit breakers and similar devices for household
and similar applications. The text of the draft was submitted to the Unique Acceptance Procedure and was
approved by CENELEC on 2007-05-07.

Subclauses 9.10.2.1 and 9.10.2.2
9.10.2.1 General test conditions
For the lower values of the test current of 9.10.2.2, 9.10.2.3 and 9.10.2.4 respectively the test is made
once, at any convenient v
...

  • Relates Information
  • IEC 60300-3-7:1999

    IEC 60300-3-7:1999 - Dependability management - Part 3-7: Application guide - Reliability stress screening of electronic hardware Released:5/31/1999 Isbn:2831847974
    09-20
  • HD 571 S1:1990

    HD 571 S1:1998
    09-20
  • ISO 8130-4:1992

    ISO 8130-4:1992 - Coating powders
    09-20
  • HD 478.2.7 S1:1990

    HD 478.2.7 S1:2003
    09-19
  • ISO 8473:1988/Cor 1:1992

    ISO 8473:1988/Cor 1:1992 - Information processing systems — Data communications — Protocol for providing the connectionless-mode network service — Technical Corrigendum 1 Released:12/10/1992
    09-19
  • EN ISO 9013:2017/prA1

    EN ISO 9013:2017/oprA1:2024
    09-19
  • IEC 60118-6:1999

    IEC 60118-6:1999 - Hearing aids - Part 6: Characteristics of electrical input circuits for hearing aids Released:6/9/1999 Isbn:2831848075
    09-19
  • HD 280.3 S1:1990

    HD 280.3 S1:1999
    09-19
  • ISO 9832:1992

    ISO 9832:1992 - Animal and vegetable fats and oils -- Determination of residual technical hexane content
    09-19
  • EN 60188:1988/A1:1990

    EN 60188:1999/A1:1999
    09-18