STANDARD
SIST EN 3662-005:2009
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 3662-005August 2006ICS 49.060 English VersionAerospace series - Circuit breakers, three-pole, temperaturecompensated, rated current 20 A to 50 A - Part 005: Withpolarized signal contact - Product standardSérie aérospatiale - Disjoncteurs tripolaires compensés entempérature, intensités nominales 20 A à 50 A - Partie 005: Avec contact de signalisation polarisé - Norme de produitLuft- und Raumfahrt - Schutzschalter, dreipolig,Temperaturkompensiert, Nennströme von 20 A bis 50 A -Teil 005: Mit polarisiertem Signalkontakt - ProduktnormThis European Standard was approved by CEN on 5 June 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2006 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 3662-005:2006: ESIST EN 3662-005:2009
EN 3662-005:2006 (E) 2 Contents Page Foreword.3 1 Scope.4 2 Normative references.4 3 Dimensions and mass.4 4 Characteristics.6 5 Designation.11 6 Rated current code.11 7 Delivery codes.12 8 Marking.12 9 Technical specification.12
SIST EN 3662-005:2009
EN 3662-005:2006 (E) 3 Foreword This European Standard (EN 3662-005:2006) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2007, and conflicting national standards shall be withdrawn at the latest by February 2007. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
SIST EN 3662-005:2009
EN 3662-005:2006 (E) 4 1 Scope This standard specifies the characteristics of three-pole circuit breakers, temperature compensated with a rated current from 20 A to 50 A, used in aircraft on-board circuits at a temperature between − 55 °C and 90 °C and at an altitude of 15 000 m max. These circuit breakers are operated by a push-pull type single push button (actuator), with delayed action "trip-free" tripping with a polarized signal contact which is open when main contacts are closed, and inversely. They will continue to function up to the short-circuit current. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 3155-016, Aerospace series — Electrical contacts used in elements of connection — Part 016: Contacts, electrical, male, type A, crimp, class S — Product standard. EN 3662-001, Aerospace series — Circuit breakers, three-pole, temperature compensated, rated current 20 A to 50 A — Part 001: Technical specification. EN 3841-305, Aerospace series — Circuit breakers — Test methods — Part 305: Short-circuit performance. EN 6113, Aerospace series — Circuit breaker, connecting and attachment hardware.1) TR 6083, Aerospace series — Cut-outs for installation of electrical components.2) MIL-I-81969/1A, Installing and removal tools, connector electrical contact, type III, class 2, composition C.3) MIL-I-81969/14C, Installing and removal tools, connector electrical contact, type III, class 2, composition B.3) MIL-S-19500, Semiconductor device, diode, silicon, fast recovery.3) FED-STD-595B, Colors used in Government Procurement. 3 Dimensions and mass 3.1 Dimensional characteristics The circuit breakers do not have to correspond to the pictorial illustration, only the dimensions given shall be ad
...