SLOVENSKI STANDARD
01-december-2022
Mehanske vibracije in udarci - Vibracije dlan-roka - Merjenje in vrednotenje
prenosov vibracij z rokavice na dlan roke - Dopolnilo A2 (ISO 10819:2013/Amd
2:2021)
Mechanical vibration and shock - Hand-arm vibration - Measurement and evaluation of
the vibration transmissibility of gloves at the palm of the hand - Amendment 2 (ISO
10819:2013/Amd 2:2021)
Mechanische Schwingungen und Stöße - Hand-Arm-Schwingungen - Messung und
Bewertung der Schwingungsübertragung von Handschuhen in der Handfläche -
Änderung 2 (ISO 10819:2013/Amd 2:2021)
Vibrations et chocs mécaniques - Vibrations main-bras - Mesurage et évaluation du
facteur de transmission des vibrations par les gants à la paume de la main -
Amendement 2 (ISO 10819:2013/Amd 2:2021)
Ta slovenski standard je istoveten z: EN ISO 10819:2013/A2:2022
ICS:
13.160 Vpliv vibracij in udarcev na Vibration and shock with
ljudi respect to human beings
13.340.40 Varovanje dlani in rok Hand and arm protection
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN ISO 10819:2013/A2
EUROPEAN STANDARD
NORME EUROPÉENNE
October 2022
EUROPÄISCHE NORM
ICS 13.160; 13.340.40
English Version
Mechanical vibration and shock - Hand-arm vibration -
Measurement and evaluation of the vibration
transmissibility of gloves at the palm of the hand -
Amendment 2 (ISO 10819:2013/Amd 2:2021)
Vibrations et chocs mécaniques - Vibrations main-bras Mechanische Schwingungen und Stöße - Hand-Arm-
- Mesurage et évaluation du facteur de transmission Schwingungen - Messung und Bewertung der
des vibrations par les gants à la paume de la main - Schwingungsübertragung von Handschuhen in der
Amendement 2 (ISO 10819:2013/Amd 2:2021) Handfläche - Änderung 2 (ISO 10819:2013/Amd
2:2021)
This amendment A2 modifies the European Standard EN ISO 10819:2013; it was approved by CEN on 31 August 2022.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of
this amendment into the relevant national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 10819:2013/A2:2022 E
worldwide for CEN national Members.
Contents Page
European foreword . 3
Annex ZA (informative) Relationship between this European Standard and the essential
health and safety requirements of Regulation (EU) 2016/425 aimed to be covered . 4
European foreword
This document (EN ISO 10819:2013/A2:2022) has been prepared by Technical Committee ISO/TC 108
"Mechanical vibration, shock and condition monitoring" in collaboration with Technical Committee
CEN/TC 231 “Mechanical vibration and shock” the secretariat of which is held by DIN.
This Amendment to the European Standard EN ISO 10819:2013 shall be given the status of a national
standard, either by publication of an identical text or by endorsement, at the latest by April 2023, and
conflicting national standards shall be withdrawn at the latest by April 2023.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document has been prepared under a standardization request M/571/C(2020) 7924 final given to
CEN/CENELEC by the European Commission and the European Free Trade Association, and supports
the essential health and safety requirements of Regulation (EU) 2016/425.
For the relationship with EU Directive(s) / Regulation(s), see informative Annex ZA, which is an integral
part of this document.
Any feedback and questions on this document should be directed to the users’ national standards
body/national committee. A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of
North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and the
United Kingdom.
Endorsement notice
The text of ISO 10819:2013/Amd 2:2021 has been approved by CEN as EN ISO 10819:2013/A2:2022
without any modification.
Annex ZA
(informative)
Relationship between this European Standard and the essential health and
safety requirements of Regulation (EU) 2016/425 aimed to be covered
This document has been prepared under a Commission’s standardization request M/571/C(2020) 7924
final to provide one voluntary means of conforming to essential health and safety requirements of
Regulation (EU) 2016/425 of the European Parliament and of the Council of 9 March 2016 on personal
protective equipment.
Once this standard is cited in the Official Journal of the European Union under that Regulation
(EU) 2016/425, compliance with the normative clauses of this standard given in Table ZA.1 confers,
within the limits of the scope of this standard, a presumption of conformity with the corresponding
essential health and safety requirements of that Regulation (EU) 2016/425 and associated EFTA
regulations.
Table ZA.1 — Correspondence between this European Standard and
Annex II of Regulation (EU) 2016/425
Essential health and safety Clause(s)/sub-clause(s) Remarks/Notes
Requirements of Regulation of this EN
(EU) 2016/425
3.1.3 Mechanical vibration Clause 9 None
WARNING 1 — Presumption of conformity stays valid only as long as a reference to this European
Standard is maintained in the list published in the Official Journal of the European Union. Users of this
standard should consult frequently the latest list published in the Official Journal of the European
Union.
WARNING 2 — Other Union legislation may be applicable to the product(s) falling within the scope of
this standard.
INTERNATIONAL ISO
STANDARD 10819
Second edition
2013-07-15
AMENDMENT 2
2021-08
Mechanical vibration and shock —
Hand-arm vibration — Measurement
and evaluation of the vibration
transmissibility of gloves at the palm
of the hand
AMENDMENT 2
Vibrations et chocs mécaniques — Vibrations main-bras — Mesurage
et évaluation du facteur de transmission des vibrations par les gants à
la paume de la main
AMENDEMENT 2
Reference number
ISO 10819:2013/Amd.2:2021(E)
©
ISO 2021
ISO 10819:2013/Amd.2:2021(E)
© ISO 2021
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: [email protected]
Website: www.iso.org
Published in Switzerland
ii © ISO 2021 – All rights reserved
ISO 10819:2013/Amd.2:2021(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/ patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www .iso .org/
iso/ foreword .html.
This document was prepared by Technical Committee ISO/TC 108, Mechanical vibration, shock and
condition monitoring, Subcommittee SC 4, Human exposure to mechanical vibration and shock, in
collaboration with the European Committee for Standardization (CEN) Technical Committee CEN/
TC 231, Mechanical vibration and shock, in accordance with the Agreement on technical cooperation
between ISO and CEN (Vienna Agreement).
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/ members .html.
ISO 10819:2013/Amd.2:2021(E)
Mechanical vibration and shock — Hand-arm vibration
— Measurement and evaluation of the vibration
transmissibility of gloves at the palm of the hand
AMENDMENT 2
9.3.3
Replace the title with the following:
“Lacks (gaps) in the vibration-reducing material”
9.3.3.1
Replace the text with the following:
“Antivibration gloves may be fabricated in which the vibration-reducing material placed in the thumb
and finger sections of the gloves is not directly connected to the adjacent vibration-reducing material
placed in the palm section. In some constructions of the gloves (for example in large nubs), the gaps can
also lie in other areas. Likewise, these gaps should not be too large in relation to the material thickness.
In cases where the vibration-reducing material placed in the thumb and finger sections of the gloves
is not directly connected to the adjacent vibration-reducing material placed in the palm section, the
following requirements shall be met.”
9.3.3.3
Replace the text with the following:
“Lacks (gaps) between the thumb and finger sections and the palm vibration-reducing material
The lacks (gaps) in the vibration-reducing material such as those between the thumb and finger sections
and the adjacent palm vibration-reducing material section shall not be greater than the thickness of the
palm vibration-reducing material section along the length of the lacks.
The evaluation shall follow the procedure defined in Annex C.”
9.3.3.4
Replace the text with the following:
“Securing of the vibration-reducing material in the thumb and finger sections
The vibration-reducing material in the thumb and finger sections shall be secured in the gloves so that
the material does not slip or come out of position during normal use of the gloves.”
ISO 10819:2013/Amd.2:2021(E)
9.3.3.5
Add the following subclause after 9.3.3.4:
“9.3.3.5 Other lacks (gaps) in the vibration-reducing material
In some constructions of the gloves (for example in large nubs), the gaps can also lie in other areas.
Likewise, these gaps should not be too large in relation to the material thickness.
The evaluation should follow the procedure defined in Annex C.”
Annex C
Add the following annex after Annex B, before the Bibliography:
2 © ISO 2021 – All rights reserved
ISO 10819:2013/Amd.2:2021(E)
Annex C
(normative)
Test procedure for verification of the gaps (interspace) between
the vibration-reducing material
C.1 General
Depending on the construction of the gloves, there may be gaps in the vibration-reducing material for
improving dexterity. There cou
...