SIST EN 14527:2006/kprA1:2010
01-maj-2010
.DGL]DSUKDQMH]DGRPDþRXSRUDER
Shower trays for domestic purposes
Duschwannen für den Hausgebrauch
Receveurs de douche à usage domestique
Ta slovenski standard je istoveten z: EN 14527:2006/FprA1
ICS:
91.140.70 Sanitarne naprave Sanitary installations
SIST EN 14527:2006/kprA1:2010 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 14527:2006/kprA1:2010
---------------------- Page: 2 ----------------------
SIST EN 14527:2006/kprA1:2010
EUROPEAN STANDARD
FINAL DRAFT
EN 14527:2006
NORME EUROPÉENNE
EUROPÄISCHE NORM
FprA1
March 2010
ICS 91.140.70
English Version
Shower trays for domestic purposes
Receveurs de douche à usage domestique Duschwannen für den Hausgebrauch
This draft amendment is submitted to CEN members for second unique acceptance procedure. It has been drawn up by the Technical
Committee CEN/TC 163.
This draft amendment A1, if approved, will modify the European Standard EN 14527:2006. If this draft becomes an amendment, CEN
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of this amendment
into the relevant national standard without any alteration.
This draft amendment was established by CEN in three official versions (English, French, German). A version in any other language made
by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same
status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2010 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 14527:2006/FprA1:2010: E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN 14527:2006/kprA1:2010
EN 14527:2006/FprA1:2010 (E)
Foreword
This document (EN 14527:2006/FprA1:2010) has been prepared by Technical Committee CEN/TC 163
“Sanitary appliances”, the secretariat of which is held by UNI.
nd
This document is currently submitted to the 2 UAP.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA which is an integral part of this document.
This document supports the unified approach for CE marking of sanitary appliances covered by harmonised
European Standards elaborated by CEN/TC 163 under the Mandate M/110 "Sanitary appliances".
2
---------------------- Page: 4 ----------------------
SIST EN 14527:2006/kprA1:2010
EN 14527:2006/FprA1:2010 (E)
1 Modification to Clause 1 “Scope”
In the first paragraph, delete the wording “of cleanability”.
2 Modification to sub-clause 3.3
Replace with the following:
“3.3
durability
attributes of materials and their surfaces intended to come into contact with water, which allow the anticipated
working life of the product”.
3 Insertion of new Clause 4 as follows:
“4 Classification
Class 1: Products complying with the requirements of Clause 5
Class 2: Products complying with the requirements of Clause 6”
Renumber and modify all cross references accordingly.
4 Modification to the heading of the renumbered Clause 5 (former Clause 4) as
follows:
Replace
“5 Requirements”
with
“5 Requirements for class 1 products”
5 Modification to the renumbered sub-clause 5.3.1 as follows: (former sub-clause
4.3.1)
Delete “of cleanability” at the end of the sentence.
6 Deletion of the renumbered sub-clause 5.4 “Dangerous substances” (former sub-
clause 4.4)
3
---------------------- Page: 5 ----------------------
SIST EN 14527:2006/kprA1:2010
EN 14527:2006/FprA1:2010 (E)
7 Insertion of new Clause 6 as follows:
“6 Requirements for class 2 products
6.1 General
The manufacturer shall provide instructions with each shower tray covering installation and care.
NOTE Annex B gives advice which manufacturers can include in their instructions.
6.2 Cleanability
6.2.1 Appearance of surface
When a shower tray is inspected under strong and oblique illumi
...