SLOVENSKI STANDARD
01-september-2022
Nadomešča:
SIST EN ISO 5167-1:2004
Merjenje pretoka fluida na osnovi tlačne razlike, povzročene z napravo, vstavljeno
v polno zapolnjen vod s krožnim prerezom – 1. del: Splošna načela in zahteve (ISO
5167-1:2022)
Measurement of fluid flow by means of pressure differential devices inserted in circular
cross-section conduits running full - Part 1: General principles and requirements (ISO
5167-1:2022)
Durchflussmessung von Fluiden mit Drosselgeräten in voll durchströmten Leitungen mit
Kreisquerschnitt - Teil 1: Allgemeine Grundlagen und Anforderungen (ISO 5167-1:2022)
Mesurage de débit des fluides au moyen d'appareils déprimogènes insérés dans des
conduites en charge de section circulaire - Partie 1: Principes généraux et exigences
générales (ISO 5167-1:2022)
Ta slovenski standard je istoveten z: EN ISO 5167-1:2022
ICS:
17.120.10 Pretok v zaprtih vodih Flow in closed conduits
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN ISO 5167-1
EUROPEAN STANDARD
NORME EUROPÉENNE
June 2022
EUROPÄISCHE NORM
ICS 17.120.10 Supersedes EN ISO 5167-1:2003
English Version
Measurement of fluid flow by means of pressure
differential devices inserted in circular cross-section
conduits running full - Part 1: General principles and
requirements (ISO 5167-1:2022)
Mesurage de débit des fluides au moyen d'appareils Durchflussmessung von Fluiden mit Drosselgeräten in
déprimogènes insérés dans des conduites en charge de voll durchströmten Leitungen mit Kreisquerschnitt -
section circulaire - Partie 1: Principes généraux et Teil 1: Allgemeine Grundlagen und Anforderungen (ISO
exigences générales (ISO 5167-1:2022) 5167-1:2022)
This European Standard was approved by CEN on 14 June 2022.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 5167-1:2022 E
worldwide for CEN national Members.
Contents Page
European foreword . 3
European foreword
This document (EN ISO 5167-1:2022) has been prepared by Technical Committee ISO/TC 30
"Measurement of fluid flow in closed conduits" in collaboration with Technical Committee CEN/SS F05
“Measuring Instruments” the secretariat of which is held by CCMC.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by December 2022, and conflicting national standards
shall be withdrawn at the latest by December 2022.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN ISO 5167-1:2003.
Any feedback and questions on this document should be directed to the users’ national standards
body/national committee. A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of
North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the
United Kingdom.
Endorsement notice
The text of ISO 5167-1:2022 has been approved by CEN as EN ISO 5167-1:2022 without any
modification.
INTERNATIONAL ISO
STANDARD 5167-1
Third edition
2022-06
Measurement of fluid flow by means of
pressure differential devices inserted
in circular cross-section conduits
running full —
Part 1:
General principles and requirements
Mesurage de débit des fluides au moyen d'appareils déprimogènes
insérés dans des conduites en charge de section circulaire —
Partie 1: Principes généraux et exigences générales
Reference number
ISO 5167-1:2022(E)
ISO 5167-1:2022(E)
© ISO 2022
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: [email protected]
Website: www.iso.org
Published in Switzerland
ii
ISO 5167-1:2022(E)
Contents Page
Foreword .v
Introduction . vi
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
3.1 Pressure measurement . 2
3.2 Primary devices . . 2
3.3 Flow . 3
4 Symbols and subscripts . 6
4.1 Symbols . 6
5 Principle of the method of measurement and computation . 7
5.1 Principle of the method of measurement . 7
5.2 Method of determination of the required diameter ratio for the selected standard
primary device . 8
5.3 Computation of flow rate . . 8
5.4 Determination of density, pressure and temperature . 8
5.4.1 General . 8
5.4.2 Density . 9
5.4.3 Static pressure . 9
5.4.4 Temperature . 9
5.5 Differential pressure flow measurement system . 10
5.5.1 General . 10
5.5.2 Primary device . 11
5.5.3 Impulse lines and transmitters .12
5.5.4 Impulse line isolation valves and valve manifolds .12
5.5.5 Flow computer . .12
5.6 Differential pressure flow measurement system design considerations .12
5.6.1 Flow rate turndown and stacked transmitters .12
5.6.2 Meter calibration .12
5.6.3 Permanent pressure loss . 13
5.6.4 Diagnostics and meter verification . 14
5.6.5 Overall uncertainty of differential pressure metering system . 14
6 General requirements for the measurements .14
6.1 Primary device . 14
6.2 Nature of the fluid. 15
6.3 Flow conditions . 15
7 Installation requirements .15
7.1 General . 15
7.2 Minimum upstream and downstream straight lengths . 17
7.3 General requirement for flow conditions at the primary device . 17
7.3.1 Requirement . 17
7.3.2 Swirl-free conditions . 17
7.3.3 Good velocity profile conditions . 17
7.4 Flow conditioners . 17
7.4.1 Compliance testing .
...