1. The extinguisher switch is not activatedand the extinguisher wire is shorted. Lack of automatic oil protection.
2. Sensor: Disconnect the oil sensor cable and replace the oil sensor if the gasoline engine can start.
3. Ignition system problems:Disconnect the spark plug and start the engine without loading, and observe the spark if it is white and red, replace it. no spark, replace spark plug or igniter.
4. Fuel systemproblems: Check to see if water has entered the fuel. If water has entered, clean the carburetor with gasoline. To determine if fuel has entered the cylinder, disconnect the spark plug and press the air filter hole firmly with your finger. Pull it to start several times and smell the fuel with your finger. DeterminedCheck if there is an air leak in the oil supply channel and change the position of the shock absorber to see if it can start.
Precautions for gasoline generators
Please note that the generator should be installed in a place out of reach of passers-by and children.
Never place flammable objects near the exhaust vent when the generator is running.
The distance between this generator and buildings or other devices should be kept at least 1 meter. Otherwise, the generator will overheat. Do not cover the dust cover when the generator is running.
Gasoline generators often stall automatically during operation. There are several reasons. One is lack of oil, the other is the oil circuit blocked, the third is the body temperature is too high. and the fourth is The load is too great. These situations will lead to callusautomatic age of the gasoline generator during operation.
If the machine is not very old or old, it is recommended to replace the spark plug and carburetor. If it is certain that the spark plug is not the fault, it is recommended that the oil supply line is not slick and cleaned or replaced.
Detailed information:
How to store gasoline generators when not in use used for a long period of time:
1. Empty all gasoline from the fuel tank and carburetor;
2. Drain all the oil from the crankcase
3. The engine oil reaches the upper limit of the oil level on the oil dipstick;
4. Close the choke and pull the starter handle to where resistance is felt;
5. Clean the device, cover it with cardboard or a plastic cover to prevent dust.