1. The diesel generator set cannot start normally or the speed is too low
Starting problems may be caused by the following reasons:
1. This may be because the battery power of the Shangchai generator set is insufficient. The electrolyte should be checked and charged before starting, and the battery can be replaced directly if necessary.
2. This may be because there is water in the generator. At the moment you are not allowed to dismantle the generator without permission. Please contact the maintenance personnel of the diesel generator manufacturer, such as Yangzhou Fukangsi, immediately.
3. This may be because the lubricating oil temperature is low. At this time, the oil pan lubricating oil heater should be installed.
2. Diesel generator cannot startand smoke
If you are experiencing smoking problems, it may be due to the following reasons:
1. This may be due to insufficient preheating before starting. Before starting the generator, it must be fully preheated. At the same time, carefully check the wires and the glow relay.
2. This may be due to the presence of air in the fuel. At this point, the air should be released and fuel can flow normally from the oil return pipe via the manual fuel pump.
3. This may be due to the wrong type of fuel being used. At this point, the original fuel should be replaced and the correct type of fuel should be used.
3. Diesel generator set automatic shutdown
When you encounter automatic shutdown problem, it may be due to the following reasons:
1. It may be due to a insufficient fuel supplynt. Usually, the speed gradually slows down and gradually stops during normal operation, but various indicators (including pressure, water temperature, oil temperature, etc.) appear normal. At this point, fuel must be provided on time.
2. This may be due to obstruction in moving parts, such as piston failure. Usually, the engine oil is normal during operation, but the operation is difficult and accompanied by abnormal noises, the oil temperature rises and is accompanied by paint smell, and the water cannot come out of the cooling port. At this time, it is necessary to check the operation of the flywheel.