Please read the instructions carefully before use:
1. Before use, you must add special engine oil for gasoline engines (four-stroke gasoline engine oil). the generator must be placed horizontally without overflowing. There is not enough oil. The machine will not start and too much oil will damage the engine. It is best to use standard engine oil above SG level. Change the oil after 20 hours of operation for the new machine and change the oil every 100 hours for the second time. After that, the oil will be changed according to the color of the oil.
2. The gasoline must be clean and compliant with standards (gasoline greater than 93#). Please use the fuel filter when filling. Do not overfill to avoid overflowing due to heat. the machine is working, to avoid fires. 3. Start the cold engine: open the throttle valve of the carb valveurant, close the ignition switch, put the damper in the closed state (toward the panel side), gently pull the pull plate cable when you feel resistance, quickly pull the cable. and loudly, and the engine starts, gently lower the cable and put the shock absorber in the open state (do not start under load). 4. After the generator starts, observe that the generator voltmeter reads normal before plugging in the output jack, turning off the output switch, and energizing the equipment. If the displayed voltage exceeds 240 V or is lower than 180 V, do not supply power. to the equipment to avoid unnecessary losses.
5. When you turn off the generator, you must first turn off the output switch - close the oil valve - and turn off the ignition switch. 6. The fuel filter screen and air filter core at the bottom of the fuel tank should be checked and cleaned regularly. The core ofair filter must not be disturbed. After cleaning with a neutral detergent (hot soapy water is also acceptable), dry it. the rest of the detergent and let it dry. 7. Do not replace spark plugs casually, otherwise the engine will be damaged.
8. If the generator fails to start, runs erratically, shakes or stalls during operation, this is usually due to a clogged carburetor. The fault can be eliminated after cleaning the carburetor. do not adjust the throttle and carburetor speed.
10. If the voltmeter has no voltage value indication after the generator starts to work normally and there is no voltage output when the output switch is closed
This phenomenon is a waste of excitement. default. When the generator is running When 12V power is used, momentarily touch the output jack and the generator will return immediatelyto normal. 11. Do not connect the generator to the building's electrical system.
12. Generators should be used in a ventilated area. Exhaust gases contain a large amount of toxins and inhaling large quantities will cause death.
Fuheng Generator will give you the answer for your reference and we hope to adopt it.