The switching method of the floor heating water distributor is as follows:
1. If you want to open the underfloor heating water distributor, you need to turn it. the switch on the underfloor heating water distributor. The main valve should be kept parallel to the water line and the five water diversion valves above it should be kept vertical to open it.
2. If you want to close the water distributor of the underfloor heating, you need to keep the main valve vertical to the water pipe and keep the five valves of the water distributor parallel above, then you can close. he.
Precautions for using the floor heating water dispenser
1. When the floor heating water dispenser is not in use, you cannot turn off all the switches of the floor heating water dispenser you needin. to close the main valve. The volume of circulating water must be reduced to better protect the underfloor heating water distributor and thus not affect its lifespan.
2. If the heating is not smooth during heating in winter, you need to manually vent the air in the floor heating pipe. You can exhaust the air inside through the exhaust valve, so you can use it hot. water normally.
What is the installation height of the floor heating sub-sensor? How to adjust the floor heating sub-collector
Northern friends usually install floor heating in their houses. If they don't know about underfloor heating, maybe only people from the south do. Actually, underfloor heating is really a very common thing in the north, because they have to rely on underfloor heating for winter, but people who know about underfloor heating sYou also need to know that when installing floor heating, the water distributor of the floor heating always looks very ugly. . Therefore, everyone tries their best to cover it up. So where do you usually buy the covers to cover the floor heating water dispenser? buy 1. The brand comes to design the cover of the floor heating water dispenser. Some professional decoration companies or installation companies can come and measure the part and then design and produce it professionally.
2. Purchase in physical stores. In addition, we can also go to specialized stores to purchase covers for underfloor heating water dispensers. This method of purchasing will be more convenient and the purchased products will be safer after all. , we saw the products in person. If you buy again, you can be sure of the quality of the product.
3. Online Purchase Moreover, the cover of this water dispenser can also be purchased online. After all, we are in the Internet age and many things can be successfully purchased without leaving home. -home delivery, extremely convenient. But the disadvantage of this method is that the quality cannot be guaranteed.
After understanding where to buy the cover for the floor heating water dispenser, let's learn how to cover the floor heating water dispenser in general!
How to cover the floor heating water distributor in general? It is said that the water distributor of underfloor heating can be blocked with a special protective casing, and this method is also very easy to use and practical. It can not only beautify the environment, but also effectively protect the water dispenser. product. .
1. Advantages of water dispenser protection boxunderfloor heatingBlock boxes are usually boxes hidden in kitchen cabinets. Although there are also exposed boxes, concealed boxes can not only save space, but also satisfy the aesthetics of the house.
2. The price of the protective casing of the underfloor heating water distributor. The price of the protective casing of the floor heating water dispenser does not have a clear number, because its price depends on the brand, brand of auxiliary materials. , installation cost, material, etc. It matters, the price will be different if the conditions are different, so it should always be based on personal choice.
3. The material of the protective casing of the underfloor heating water distributor. There are still many protective casing materials on the market. Generally, most people will choose aluminum-plastic panels, but if you likeez the texture, you can. also choose It is made of artificial stone, but this material is very bulky and difficult to transport.
After installing a water dispenser for underfloor heating, everyone usually wants to cover it with something because it doesn't look good. Then you can also try to cover it with a blocking box or cover, so that your house looks more beautiful.
Front address of Jincheng Kanghui floor heating water dispenser
1. Installation height of floor heating water collector
In fact, the installation of floor heating water collector should be divided into two parts. : One is the installation of the floor heating water distributor and the other is the installation of the floor heating water collector. The installation heights of these two different components are inconsistent.
1. The installation height of the water dispenserfloor heating water distributor
Floor heating water distributor refers to the water distribution rod connected to our outdoor water supply pipe. This water dispenser allows you to divide the incoming water into different circuits and then provide heat to the room. Therefore, its installation position is generally high on the upper side.
Height requirements: At present, the most common installation height of floor heating water dispenser is generally 600mm from the finished floor surface . That's to say. When we determine the height of the underfloor heating water dispenser, simply measure up to 600mm from the floor based on the center line of the water dispenser pipe.
2. The installation height of the floor heating water collector
The floor heating water collector is connected to the main indoor water return pipe. Its functionst to collect the water after the internal water. the supply has been distributed. It then passes through the main water return pipe and returns to the outdoor heating pipe network. Therefore, the main water return pipe is usually installed on the lower side of the water dispenser, which is higher than the main water supply pipe.
Height requirements: The common installation height requirement for the water collector main pipe is approximately 400mm from the finished floor surface. The specific measurement method is to measure a height of 400mm from the ground and stretch the line on the wall. This line is the center line of the main water collection pipe.
2. Method of adjusting the underfloor heating sub-manifold
1. Slow switch for the first time
When the installed floor heating is started for the first time. , it is necessary to openlaugh the underfloor heating sub-collector. The water supply valve to the water heater. Horizontal state means open and vertical state means closed. At this time, you should pay attention to the slow opening speed. If you open it directly, the underwater water collector will open. Leakage, hot water will spurt out directly, which is dangerous.
2. Debugging the exhaust for the first time
As with the radiator, there will be a lot of air in the installed floor heating pipes. Underfloor heating pipes are long and circuitous. , which can easily cause air blockage and the circulation of floor heating is not good. It is difficult to achieve normal heat dissipation if it is unblocked. It is essential to debug the escape in time. Close all valves before draining and drain them one by one.
3. Cleaning work
The inside of the underfloor heating water collector chas a component that blocks impurities - a filter. Impurities present in the construction of heating water and underfloor heating can accumulate in the water collector filter, so this must be removed and cleaned regularly. Before cleaning, close all valves, use a wrench to open the filter counterclockwise, remove the inner mesh and rinse.
4. Flexible temperature adjustment
Adjust the temperature via the water supply valve of the underfloor heating water collector. Specifically, set the water supply valve to maximum and the water flow will adjust. improve the heat dissipation in the room, making it faster and warmer, conversely, turning it down will lower the temperature when you go out temporarily or on a business trip. It should be noted that when heating begins, the underfloor heating will heat up slowly for approx.n 2 days, so don't act too quickly.
If there is no heat, you can evacuate the water and air according to the circuit of the room to clear the pipes.
Zhuangjing Community, Zhuangjing Street, Jincheng Town. Its Jincheng Kanghui floor heating water distributor is located in Zhuangjing Community, Zhuangjing Street, Jincheng Town. It is a company mainly engaged in the wholesale business. The full name of underfloor heating is radiant floor heating, which refers to the installation of a layer of heating material under the wooden floor or under the ceramic tiles.