The generator room is an important part of the power plant. However, due to the noisy operation of the generator, it will cause great noise pollution to nearby residents. It is therefore necessary to consider the problem of soundproofing the generator room.
To resolve this issue, we can use the following methods to resolve it:
1. Install a soundproof wall: The appearance of the soundproof wall can be made of materials that are in harmony with the environment and beautified, effectively isolate the noise inside the generator room.
2. Use soundproof doors: Soundproof doors can effectively prevent noise from spreading laterally and can also prevent noise from escaping through door gaps. Therefore, installing soundproof doors is also a very important method.
3. Reduce the operating speed of the unit : Reducing the operating speed of the unit can effectively reduce the occurrence of noise. At the same time, reducing the usage time of the device can also reduce the impact of noise.
In general, sound insulation in the generator room can not only reduce the impact of noise on the environment, but also is a necessary measure to ensure the normal operation of the generator set.
What should you pay attention to when installing a diesel generator? Are there any requirements for the engine room?
General ventilation and process air supply to the diesel engine room are carried out by HVAC professionals. Others are determined by the electrical major. To put it simply: when the diesel engine room is not producing electricity, the air supply and exhaust is provided by HVAC professionals and when the machinesof the diesel engine room are operating, process air supply is also provided at this time by the HVAC department; . As with process smoke extraction, these are determined by the electrical sector.
Yangzhou “Walter” engineers will answer for you:
The computer room should have enough space to allow free circulation of air, which is important to ensure the normal operation of the unit, reduce the power loss of the unit and ensure the normal life of the unit is very important.
Other flammable and explosive objects should not be placed inside the engine room, nor any object that could easily get stuck in the unit's protective grille or even be sucked in directly into the machine body, which may affect the normal use of the device. In order to prevent the reflux of hot air, an air guide hood is installed inbe the unit's cooling water tank and air outlet to prevent hot air from circulating inside.
For the installation and construction of units that generally do not have special requirements, the design requirements of the computer room are not high. It is enough to ensure that the air inlet and outlet of the computer room can be. ensured assuming that the exhaust back pressure does not exceed the specified value. The air outlet meets the requirements of technical specifications and avoids heating backflow, and sufficient space for operation and maintenance can be reserved inside the engine room.
The air intake volume of the engine room must be ensured to supplement the air consumed for engine combustion and to remove the large amount of heat emitted by the unit from the exterior of the engine room through the core of the radiator, so that the temperature in the engine room is as close as possible to the ambient temperature and maintains the body temperature within the normal operating range. It should be ensured that the minimum net area of the air outlet is not less than 1.25 times the effective area of the radiator core. The center position of the air outlet should be consistent with the center position of the unit's radiator core. as much as possible. The aspect ratio of the air outlet should also be as consistent as possible with the radiator core. The aspect ratio of the cores is the same.