Precautions for safe use of generators
1. Generator exhaust is toxic. Do not use it in a closed place. Please use it in a well-ventilated area.
2. Be sure to turn off the generator when refueling.
3. Do not smoke while refueling or refuel near a flame.
4. Be careful not to overflow or spill fuel on the engine when refueling.
5. Please keep the generator upright when operating or moving it. There is a risk of fuel leakage due to tilting of the generator.
6. Please place this generator out of reach of passers-by and children.
7. When the generator is running, do not place any flammable objects near the exhaust port.
8. The distance between the generator and buildings or other devices should be kept at least 1 meter.
9. BornDo not cover the dust cover when the generator is running.
10. Do not use this generator in rain or snow. It is mandatory to use it against rain and ventilation measures must be taken.
11. When the generator is running, do not touch the machine, as there is a risk of burns or electric shock.
12. Before using the generator, the ground wire must be connected. The earth wire must be a flexible conductor of more than 4 mm2.
12. It is prohibited to connect this generator to the mains outlet.
13. It is prohibited to connect this generator to other generators.
14. Generators are strictly prohibited from operating in restricted areas with gas installations, and the safety distance must be maintained more than 30 meters.
Preparation and inspection before use
1. Fuel must be 90# gasoline (unleaded) or higher. Remove thefuel tank cap (turn counterclockwise), add fuel and observe the fuel level gauge on the tank at all times. Do not remove the fuel filter from the filler port when refueling. (When refueling, the engine must be stopped and no fireworks are allowed nearby)
2. It is prohibited to add fuel to the fuel tank when the engine is running or has not yet cooled down before adding fuel. , the oil circuit switch must be turned off.
3. When refueling, be careful not to allow dust, dirt, moisture and other external impurities to mix with gasoline. If gasoline is spilled, clean up the spilled gasoline before starting the engine.
4. For engine oil, please choose engine oil specifically designed for generators. Remove the oil dipstick and check the oil level. THEOil level should be between the dipstick grids. above the middle. Fill with engine oil once. Check the engine oil dipstick again after a few minutes to see if the oil level is appropriate.
5. There is an oil pressure sensor in the engine. If there is not enough oil, the generator cannot start normally. If there is too much oil, the generator cannot operate properly. Please drain the excess oil through the oil drain nozzle
6. The new generator is not filled with engine oil when it leaves the factory. It must be filled with engine oil before use.
How the generator works
1. It is prohibited to start the generator directly with the load. Please be sure to set the AC output switch to the (OFF) position before starting.move and connect the ground wire.
2. Turn on the fuel switch. (ON)
3. Gently remove the front shockec your fingers.
4. For manual start models, first pull the recoil starter slowly until it clicks into place, then pull hard.
5. For electric start models, set the start switch to the ON position and turn the start switch to the START position for 10 seconds; if startup fails, wait; ten seconds. Repeat until startup succeeds. If startup fails five times, check if the unit is defective.
6. Once the generator has successfully started, push the damper back in by hand.
7. When the newly purchased unit is used for the first time, it must be started repeatedly 2-3 times before it can start successfully. 8. For electric start models, when starting manually, the ignition key must be placed in the ON position.
9. Once the generator startsD at normal temperature, it should work for 1-2 minutes to preheat. When cold, the preheating time should be extended to 3 to 5 minutes. If the load is applied immediately after starting, the generator may stop abruptly.
10. The load must be properly connected to the generator output terminal before starting the generator, then turn on the output switch after preheating.
11. The generator cannot be overloaded and long-term operation with load should not exceed 80% of the rated power.
12. For three-phase generators, the three loads should be balanced, and the difference between each phase should not exceed 30%, otherwise the generator will be easily damaged.
13. To avoid personal injury or death, it must be maintained and operated by professional technicians.
14. The generator must be monitored by a dedicated personwhen it is working, and the voltage and current of the generator should be observed regularly. If any abnormality occurs, please stop the machine immediately for inspection.
15. To stop the generator, first turn off the load, then unplug the generator output switch. After running without load for 2-3 minutes, turn off the start switch to the STOP position and the fuel switch. to the STOP position.
Daily maintenance
1. Check if there is enough gasoline in the fuel tank.
2. Check the oil switch and oil pipeline for oil leaks.
3. Check if the engine oil level is between the oil dipstick grids.
4. Observe the quality of the engine oil to determine if it needs to be replaced.
5. Check whether the battery starting voltage is higher than 12V and observe whether the battery appearance is damaged or leaking.
6. The backup generator is long and the starting battery will lose power due to self-discharge. Please use an external charger to charge the battery.
7. Check the oil drain screw, seal ring and rubber ring. If damaged, please replace it immediately.
8. The engine oil should be changed immediately after the first use of the generator for 20 hours (or one month). 9. Engine oil should be replaced every 100 hours (or six months) of use. (In harsh environments, the number of times should be increased and the viscosity is SAE10W.30, API grade clean engine oil SG, SH, SJ or above)
10. The generator air filter should be cleaned every 50 hours (or three months) of use. (In harsh environments, the cleaning frequency should be increased and replaced if necessary)
11. Do not start the engine without installing thee air filter, as this will produce excessive toxic gas and cause cylinder wear.
12. Inspect the generator regularly and complete records carefully and honestly. Filling, missing or refilling without inspection is strictly prohibited.
13. The inspection record form will be completed from the beginning of this month and inspected regularly.