Diesel generatorThe oil pressure is normal in the range of 2-8 kg and the water temperature is normal below 93 CThe oil temperature is generally higher than the water temperature, about 10 degrees Celsius higher. Cummins diesel generator set type: rotating magnetic field, single bearing, 4 poles, brushless, anti-drip structure, insulation grade H, conforming to GB766, BS5000, IEC34-1 quality standards. The generator can be used in sandy, salty, seawater and chemically corrosive environments.
Cummins is the largest US investment company in China. Cummins has invested more than 140 million US dollars in China, including Dongfeng Cummins diesel generator sets and Chongqing Cummins diesel generator sets. As the largest foreign investor in China's automobile industry, Cummins now ownst joint ventures and wholly owned manufacturing companies in China, including. Dongfeng Cummins produces B, C and L series diesel engines.
Six key points for maintenance of diesel generator fuel system
1. Generally, the diesel filter element of the diesel engine of the diesel generator set needs to be cleaned once every 100 hours of operation.
2. Work for 500 hours, clean the fuel tank and pipelines, remove carbon deposits on the injector parts, calibrate the injection pressure and check the injection atomization quality.
3. There should be no leaks in the pipe joints and oil circuit seals.
4. Diesel must be precipitated and purified before being injected into the fuel tank.
5. When a diesel engine is used for the first fois after disassembly or has remained unused for a long period, the gas present in the oil circuit must be released. Bleeding method: Turn on the fuel switch and loosen the fuel injection pump bleeder screw.
6. Whether the generator's diesel engine is running or idling, the fuel tank filler cap should be closed to prevent stolen items and dust from falling into the fuel tank.