Professional: 1) The cooling water pipe in the bearing is leaking; 2) The water seal of the upper cover of the vertical unit leaks seriously, and the water enters the oil basin of the turbine guide bearing; the lubricating oil system cooler is leaking; 4) New oil is not filtered when injected into the bearing and there is water in the oil.
Generally there are only four types of letters. You can view them one by one. I hope you will accept them. Thank you~
The first thing after canceling is. to verify on site if they are true. In other words, it's possible that the interrupt signal you received came from monitoring. The second is an on-site inspection. If it turns out that the cooling water has indeed been interrupted, then the cause must be found immediately. there is no need to shut it down immediately, as the unit can usuallyoperate for some time without cooling water. Of course, if you check the cause but cannot find it and the operating temperature of the unit has exceeded the standard, stop the machine in time. The second is that if the on-site inspection of the unit cooling water is normal, check the monitoring equipment to see if there is an equipment problem.