The reasons why water-cooled electric fans cannot suck water are:
1. Insufficient water pressure, water lines that are too long, and poor pump sealing may also be present. cause The water inlet part of the pump cannot form a vacuum and water cannot be supplied.
2. Air leaks, water leaks, or a poor seal in the water supply hose will also prevent the self-priming pump from delivering water. At this point, the water pipe can be repaired or replaced.
3. When there is debris in the pump body or blocked pipes, the self-priming pump may not be able to fill water. At this point, debris must be removed to ensure this. the pipes and the pump body are unblocked.
4. When the self-priming pump is working, it requires a certain amount of priming fluidin the pump. Therefore, water should be put into the self-priming pump before use.
5. Check if there is an air leak at the leak point of the machine. If there is an air leak, it can be repaired by adding gaskets and tightening the screws.
6. Check if the turbine is blocked, causing the engine to burn. If the impeller is broken, the impeller must be replaced.
Structural principle:
Use a circulating water pump to continuously pump water into the water tank and spray it evenly on the evaporation filter layer through the water distribution system On the evaporator, the outside hot air enters the cooling fluid through evaporation.
In the CELdek evaporative cooling medium (honeycomb filter layer of special material, which makes the cooling effect more ideal, a Swedish high-tech patented product), it exchangesfully ges the heat with water, and the water is added to evaporate to absorb heat and cool, pure air is sent into the room under pressure by a low noise fan, so that the The warm air in the room is exhausted to the outside, thus achieving the indoor cooling objective.