1 liter
The coolant is proportional: for example, approximately 20 liters are added to a 30 kW diesel generator, so the conversion is 30 kW = 20 liters, 20÷ 30×1.5=1 liter Automotive coolant is mainly used in the cooling system of liquid-cooled engines. It has excellent properties such as anti-freeze in winter, anti-boil in summer, anti-limescale, and anti-corrosion.
The temperature of the cooling water is relatively high
(1) It is generally caused by the accumulation of dust on the radiator outside the water tank cooling. In case of heavy dust, debris on the outer surface of the radiator or during operation of the device will be sucked into the water tank by the cooling fan, causing blockage, blocking ventilation and resulting in poor heat dissipation.the heat. At this point, you just need to clean the radiator outside the water tank and clean the debris from the device to resolve the problem.
(2) After being used for a long time, the generator cooling fan connection belt will gradually age and become easily broken or inelastic, resulting in abnormal blowing capacity. At this point it is necessary to replace the damaged belt. When replacing, all belts should be replaced together instead of just one.
(3) The coolant content is very low. It is necessary to check the factors causing the lack of cooling water. Check the tightness of the cooling water tank and each cooling water pipe. In the event of a leak, it must be repaired immediately. Then add enough coolant.
(4) Useon a coolant that does not meet the requirements causes scale, rust and other substances to build up in the cooling water lines, which impedes the circulation of the cooling water and causes a increase in water temperature. Coolant is usually water and antifreeze or water and anti-rust fluid. The pH value of water should be between 6.0 and 8.02_, and pure water is generally used. For cooling systems that have been seriously deposited and clogged, it is best to add 0.5L of detergent for every 7L of cooling system volume, mix it with clean water, start the machine and run it for 90 rain, circulate cooling water to clean. then use clean water to circulate it Xian to prevent the cleaning agent remaining in the pipe from causing cocorrosion of the pipe.