The generator does not consume coolant.
A generator is a device that converts mechanical energy into electrical energy by rotation. It doesn't require coolant to reduce temperature like a car engine. Therefore, the generator does not actively consume coolant. Generally speaking, generators only need to maintain good ventilation and cooling conditions to ensure normal operation.
However, if the generator is interconnected to the car's cooling system, such as in a hybrid vehicle, the generator can use coolant to stabilize its temperature. But this is not a feature of the generator itself, but rather the design of the specific vehicle. In this case, if the generator fails, it may cause a leak or a decrease in coolant,thereby affecting the normal operation of the cooling system.
How much coolant is needed for a 600kw diesel generator?
The temperature of the cooling water is relatively high
(1 ) It is usually caused by dust accumulation on the radiator outside the cooling water tank. In case of heavy dust, debris on the outer surface of the radiator or during operation of the device will be sucked into the water tank by the cooling fan, causing blockage, blocking ventilation and resulting in poor heat dissipation. heat. At this point, you just need to clean the radiator outside the water tank and clean the debris from the device to resolve the problem.
(2) After being used for a long time, the generator cooling fan connection belt will age progresively and will easily become broken or inelastic, resulting in abnormal blowing capacity. At this point it is necessary to replace the damaged belt. When replacing, all belts should be replaced together instead of just one.
(3) The coolant content is very low. It is necessary to check the factors causing the lack of cooling water. Check the tightness of the cooling water tank and each cooling water pipe. In the event of a leak, it must be repaired immediately. Then add enough coolant.
(4) The use of a coolant that does not meet the requirements causes the accumulation of scale, rust and other substances in the cooling water pipes, resulting in impedes the circulation of cooling water and causes an increase in water temperature. The coolantissement is generally composed of water and antifreeze or water and anti-rust fluid. The pH value of water should be between 6.0 and 8.02_, and pure water is generally used. For cooling systems that have been seriously deposited and clogged, it is best to add 0.5L of detergent for every 7L of cooling system volume, mix it with clean water, start the machine and run it for 90 rain, circulate cooling water to clean. then use clean water to circulate it Xian to prevent the cleaning agent remaining in the pipe from causing pipe corrosion.
78 liters.
A 600 kW diesel generator requires 78 liters of antifreeze. The water in the water tank of the diesel generator set will freeze at low temperatures, especially in winter and low temperature areas.
The 600 kW diesel generatoris a large diesel generator in the power range. It is widely used in hotels, hospitals, mining areas, factories, animal husbandry, real estate, etc. as main power and backup power. provide.