First check if the engine oil and gasoline have been added recently. Otherwise, they have been added for more than three months and the oil and gasoline need to be drained and replaced. Engine oil and gasoline are only valid for three months. Oil and gasoline used for more than three months have lost their viscosity and are useless.
Check if the engine oil and generator gasoline are filled. Otherwise, the generator will not be able to turn on and start.
If the above is achieved, check if the spark plug lights. Otherwise, remove the spark plug, dip some gasoline in it and install it to see if the generator ignites. ignition and starting.
Detailed information:
The use of a gasoline generator should Note:
1) Theory guides practice. Only by fully mastering the basic principles and basic structure of petits gasoline engines we can carry out fault analysis and treatment, especially for different types of oil engines, specific analysis of specific models is required;
2) When an error occurs product. Only by carrying out comprehensive and scientific analysis and judgment based on the scene can we guarantee that the fault is handled accurately, and we cannot handle the problem based on imagination or guesswork. so-called past experience. Gasoline engines often have oil lines, circuits and other parts that fail at the same time, leading to more complex failure phenomena. Sometimes similar phenomena occur at different fault points, causing certain troubleshooting difficulties.
By connecting and analyzing the fault phenomena observed on site, by imagining different possible causes of the failure and by analyzing and coordinating themmparing, the extent and location of the fault can be determined. Then from simple to complex, from the outside to the inside, first analyze the circuit then the oil circuit, then calibrate the ignition time, check the gas distribution order, and compress the fault until 'at a certain point
3) Develop good habits, carry out necessary inspections before starting the machine and regularly inspect the machine during operation to try to avoid sudden breakdowns
4) Strictly carry out technical maintenance at all levels; oil machine to ensure that the oil The engine is in good working condition to avoid sudden breakdowns and major accidents
Reference link: Baidu Encyclopedia_Gasoline Generator
1. engine oil and gasoline Whether it is newly added, if it is not newly added and is more than three months old, you must change the engine oilr and gasoline and replace them with new ones, because engine oil and gasoline are only valid for three months, and oil and gasoline older than three months will be expired. They have lost their stickiness and have no effect.
2. The old gasoline generator is having trouble turning on. We need to check the spark plug for carbon deposits. If so, it must be cleaned or replaced with a new one. Then check if the air filter is too dirty, causing a lack of air. If so, it also needs to be cleaned or replaced. We also need to check if the engine oil has melted, because if the machine is not used for a long time, the engine oil needs to be drained. Finally, we also need to check whether the gasoline is qualified and whether it has evaporated. which results in insufficient purity and difficult ignition. Disaster.
3. Check if the boot method is correct, check if theOil switch can be activated, if the air door is closed when the cold engine starts for the first time and if the starting speed is reached, etc. First, turn on the crankcase oil drain switch, quickly fire the engine, and check the oil flow to determine the extent of the fault. If no oil comes out of the oil switch or little oil comes out, the mixture is not entering. the cylinder or the mixture is too thin. If there is a lot of oil leaking from the oil switch, the mixture is too rich. The reason may be that there is a problem with the oil supply system, or it may be that the starting method is incorrect and needs to be restarted.
4. Remove the high voltage wire from the spark plug and test for fire. If there is no spark or the spark is very weak, the magneto or high voltage wire is defective. the spark isstrong, this means the spark plug is defective or the cylinder is leaking and the mixture is poor. Confirm whether the spark plug can work normally, if not, it should be replaced in time.
5. It is difficult to start a gasoline generator. New machines require a certain break-in period. A qualified generator is not worn out, but damaged, so it is better to start the generator once a month. .-2 times.