The solutions when the gasoline generator cannot start are as follows:
1. Check if the engine oil is sufficient. When there is not much oil in the gasoline generator, especially when it is overloaded for a long time, the oil warning switch inside the engine will automatically turn off the coil. grounded ignition so that it cannot ignite normally. Gasoline must be replenished at this time.
2. Check if the automatic voltage regulator is defective. When the generator does not start normally, the automatic voltage regulator is more likely to malfunction. Remember to frequently replace the automatic voltage regulator with a new one
3. If a generator that has been unused for a long time or is too old can start normally, it is recommended to remove the regulator. spark plug and inject a little engine oil into the cylinder.And run the engine several times to improve the cylinder seal, clean the spark plug and use a lighter to remove moisture. Rushing gasoline will also affect starting. The oil in the carburetor float chamber can be renewed.
What are the reasons why the gasoline generator cannot start?
1. The main reason for the gasoline generator is to check whether the spark plug lights. If there is no ignition, replace the spark plug. If that doesn't work, you need to check the high voltage package and the problem is with the motor.
2. The oil nozzle and oil pump of the diesel generator are dirty. Just remove them and clean them with diesel.
3. If there is a problem with the fuel quality (the oil is impure or contains water), simply replace it.
4. The cylinder of gasoline engine and diesel engine is moreembarrassing. You need to open the cylinder to find out if the component is damaged.
You can search for Daze Wangxin to solve the problem for you
1. First check whether the engine oil and gasoline are newly added, whether they are not newly added and are greater than three. month, then you need to change the engine oil and gasoline and replace them with new ones, because the engine oil and gasoline are only valid for three months. Oil and gasoline that have been used for more than three months have lost their viscosity and. are useless.
2. The old gasoline generator is having trouble turning on. We need to check the spark plug for carbon deposits. If so, it must be cleaned or replaced with a new one. Then check if the air filter is too dirty, causing a lack of air. If so, it also needs to be cleaned or replaced. We also need to check if the engine oil has melted,because if the machine is not used for a long time, the engine oil must be changed. Finally, we also need to check whether the gasoline is qualified and whether it has evaporated. , resulting in insufficient purity and difficulty in inflammation.
3. Check whether the starting method is correct, check whether the oil switch can be turned on, whether the air door is closed when the cold engine starts for the first time and whether the starting speed is reached, etc. First, turn on the crankcase oil drain switch, quickly fire the engine, and check the oil flow to determine the extent of the fault. If no oil comes out of the oil switch or little oil comes out, the mixture is not entering. the cylinder or the mixture is too thin. If there is a lot of oil leaking from the oil switch, the mixture is too rich. The reason may be that there is a problem with the soil supply system, or the starting method may be incorrect and may need to be restarted.
4. Remove the high voltage wire from the spark plug and test for fire. If there is no spark or the spark is very weak, the magneto or high voltage wire is defective. If there is a fire If the spark plug is strong, it means it is defective or the cylinder is leaking and the mixture compression is poor. Confirm whether the spark plug can work normally, if not, it should be replaced in time.
5. It is difficult to start a gasoline generator. New machines require a certain break-in period. A qualified generator is not worn out, but damaged, so it is better to start the generator once a month. . -2 times.