Extruded polystyrene panel.
Extruded boards and foam boards can be used as insulation materials for underfloor heating, but extruded boards perform better in this regard. The higher density and strength of extruded polystyrene panels provide better insulation and load-bearing capacity, helping to reduce heat loss and increase the efficiency of underfloor heating systems. Extruded panels also have better compressive strength and durability, which can maintain long-term stable performance and reduce the frequency of maintenance and replacement. From the perspective of overall performance and long-term benefits, extruded polystyrene panels are the most preferred insulation material in underfloor heating systems. Of course, this is just a personal opinion and different peoplePeople may have different opinions and preferences.
Can foam boxes be used for underfloor heating?
Normal 20mm foam is sufficient. To be used as an insulating material, thermal conductivity is a very important criterion. The board has independent bubble structure, low thermal conductivity, generally less than 0.039 W/(m·k), low density and light weight.
In addition, the surface water absorption rate of the foam board is low, its anti-penetration ability is good, and it can also be recycled. Its degree of recycling is the highest among plastics. However, foam boards have poor strength and bearing capacity and are prone to cracking. If used as insulation for underfloor heating, they need to be reinforced, which is more troublesome.
Chinese floor tiles generally use pre-made tiles.manufactured or cast on site. The sound insulation effect is extremely low. People climbing stairs will affect the underfloor heating which is used to increase the insulation layer. a very good sound insulation effect and can reduce noise pollution.
Detailed information:
Construction precautions of concrete filling layer:< /p>< p >1. The construction of the concrete filling layer shall be completed within 48 hours after the installation of the floor heating pipes and the qualification of the hydraulic pressure test;
2. undertaken by civil parties qualified in construction matters. Our unit cooperates closely;
3. When constructing the concrete filling layer, the water pressure in the heating pipe should not be less than 0.6 MPa. filling layer, the water pressure of the system should not bee less than 0.4 MPa;
4. The infill layer is a structural layer used to protect the plastic pipe and even out the floor temperature. Usually it is pisolite concrete, the grain size of the stones should not be more than 10 mm, the volume ratio of cement mortar should not be less than 1:3, and the degree of strength of the concrete should not be less than C15. The thickness of the filling layer should meet the design requirements, and the flatness should not exceed 3mm;
5. The underfloor heating system must install expansion joints at the vertical intersections of walls, columns and doors; , etc. with the ground, and the width of the expansion joints must not be less than 10 mm. The width of the expansion joint must not be less than 8 mm.
Can be used for floor heating
In daily life, people use generalment of foam boards to prevent heat loss through the ground
Because the biggest advantage of using foam board is that the foam can be recycled and reused.Yes, because the foam is a recycled material, so in terms of house floor heating maintenance cost, the cost of foam board is easy to use and affordable. In addition, because the main material of foam board is foam, so its quality is relatively light and the absorption capacity of foam is not good, which means it can avoid the absorption burden by the cement floor. That is to say, it acts as a waterproof function, which is beneficial and harmless to the whole project. In addition, the thermal conductivity of the foam board is relatively low, so it has super impact resistance if the interior of the floor is almost. filled with air, then this type of foam boards can reach the rebound abilityr